Checking Port Status

Using the SEHI Hub View

Checking Port Status

You can open a Port Status window (Figure 2-9) for any port in the SEHI- controlled HUBStack. To open the Port Status window:

1. Click mouse button 1 in the Port Index box.

or

1.Click mouse button 3 in the Port Index or Port Status box to display the Port menu.

2.Drag down to Status and release.

Figure 2-9. SEHI Port Status Window

Note that the window title includes the module and port number in parentheses; the rest of the window contains the following fields:

Name

This text field can help identify the port; the information entered here is not displayed anywhere else in the Hub View.

To edit the Name:

1.Highlight the text in the Name box and type in a new name.

2.Press Enter or Return on the keyboard to save your change.

Link Status

The port’s Link Status tells you whether or not the port has a valid connection to the node at the other end of the cable segment. The possible Link conditions are:

Active — The port has a valid connection with the device at the other end of the port’s cable.