Cabletron Systems SEHI-22/24 Repeater Redundancy, Setting Network Circuit Redundancy, Chapter

Models: SEHI-22/24 SEHI-32/34

1 90
Download 90 pages 61.33 Kb
Page 45
Image 45
Repeater Redundancy

Chapter 4

Repeater Redundancy

This chapter describes how to configure and enable redundant circuits.

Setting Network Circuit Redundancy

The redundancy application gives you the ability to define redundant circuits for your SEHI to ensure that critical network connections remain operational. Each circuit has a designated primary port and one or more backup ports. The SEHI monitors the link status of the primary port’s connection to one or more network IP addresses; if the link fails, the SEHI automatically switches traffic to a backup port.

NOTE

Before you configure redundancy, make sure that only the primary physical link is connected to the network. If a backup port is connected before you configure and enable redundancy, you create a data loop.

To open the main Repeater Redundancy window:

from the icon:

1.Click on the appropriate device icon to display the icon menu.

2.Drag down to Redundancy and release.

from the Hub View:

1.Click on This chapter describes how to configure and enable redundant circuits. to display the Device menu.

2.Drag down to Redundancy and release.

from the command line (stand-alone mode):

1. From the appropriate directory, type:

4-1

Page 45
Image 45
Cabletron Systems SEHI-22/24, SEHI-32/34 Repeater Redundancy, Setting Network Circuit Redundancy, Chapter, from the icon