FIBER OPTIC PROTECTIVE CAPS

Caution READ BEFORE REMOVING FIBER OPTIC PROTECTIVE CAPS.

Cable assemblies and MMF/SMF ports are shipped with protective caps to prevent contamination. To avoid contamination, replace port caps on all fiber optic devices when not in use.

Cable assemblies and MMF/SMF ports that become contaminated may experience signal loss or difficulty inserting and removing cable assemblies from MMF/SMF ports.

Contamination can be removed from cable assemblies by

Blowing surfaces with canned duster (Chemtronics p/n ES1270 or equivalent).

Using a fiber port cleaning swab (Alcoa Fujikura LTS p/n ACT-01 or equivalent) saturated with optical-grade isopropyl alcohol, gently wipe the end surface of ferrules first; then wipe down the sides of both ferrules.

Blow ferrule surfaces dry with canned duster.

Contamination can be removed from MMF/SMF ports by

Using the extension tube supplied with canned duster, blow into the optical port, being careful not to allow the extension tube to touch the bottom of the optical port.

Reconnect cable and check for proper mating. If problems remain, gently wipe out optical port with a DRY fiber port cleaning swab and repeat step 1.

Caution To avoid contamination, replace port caps on all fiber optic devices when not in use.

vi SmartCell 6A000 User Guide

Page 6
Image 6
Cabletron Systems SmartCell 6A000 manual Fiber Optic Protective Caps