Cal Flame A726B, A734B, A515, A734L, A534, A726L, A526 manual Spa Model, GFCI Required, Wires Required

Models: A526 A726L A726B A534 A734L A515 A734B

1 32
Download 32 pages 61.6 Kb
Page 11
Image 11
Spa Model

 

Spa Model

GFCI Required

Wires Required

 

All 240V spas (except

 

 

 

6300 control boxes re-

One 50 amp GFCI

Four #8 AWG copper

 

quiring high amperage

wires

 

 

Spas

- see below)

 

 

 

 

 

Spas with the 6300

 

 

Portable

 

 

control box (when high

 

 

amperage is selected on

 

Four #8 AWG copper

circuit board)

One 60 amp GFCI

 

SEE CONFIGURATION

 

wires

 

 

 

 

INSTRUCTIONS ON

 

 

 

NEXT PAGE.

 

 

 

 

 

 

 

F2400 spa with one

One 50 amp GFCI

Four #8 AWG copper

 

5.5 kW heater

wires

 

 

 

 

 

 

 

 

Service 1: One 60

Service 1: Four #8

Spas

F2400 and FP2500 spas

amp GFCI

AWG copper wires

with two 5.5 kW heaters

Service 2: One 30

Service 2: Three #8

Fitness

 

amp GFCI

AWG copper wires

 

 

 

 

Service 1 (swim

Service 1: Four #8

 

side): One 60 amp

AWG copper wires

Ultimate

 

 

GFCI

 

FP4700 spa

Service 2 (swim

Service 2: Three #8

 

 

side): One 30 amp

AWG copper wires

 

 

GFCI

 

 

 

Service 3 (spa side):

Service 3: Four #8

 

 

One 40 amp GFCI

AWG copper wires

 

 

 

 

 

Designer in-ground spas

One 50 amp GFCI

Four #8 AWG copper

 

with one 5.5 kW heater

wires

 

 

 

 

 

 

Spas

 

Service 1: One 50

Service 1: Four #8

Designer in-ground spas

amp GFCI

AWG copper wires

-Ground

with two 5.5 kW heaters

Service 2: One 30

Service 2: Three #8

 

amp GFCI

AWG copper wires

 

Service 1: One 60

Service 1: Four #8

In

 

 

amp GFCI

AWG copper wires

 

DIJ407 spa

 

Service 2: One 30

Service 2: Three #8

 

 

 

 

amp GFCI

AWG copper wires

 

 

 

 

LTR20091024, Rev. A

9

 

Page 11
Image 11