Cal Flame A515, A734B, A734L, A534 Electrical Installation --Europe, Volt Electrical Installation

Models: A526 A726L A726B A534 A734L A515 A734B

1 32
Download 32 pages 61.6 Kb
Page 15
Image 15
Electrical Installation -- Europe

Electrical Installation -- Europe

230 Volt Electrical Installation

All 230V spas must be permanently connected (hardwired) to the power supply. These instructions describe the only acceptable electrical wiring procedure. Spas wired in any other way will void your warranty and may result in serious injury.

This is the only acceptable electrical wiring procedure. Spas wired in any other way will void your warranty. See the wiring diagram on page 15.

The electrical wiring of this spa must meet the requirements of any ap- plicable local, state, and federal codes. The electrical

circuit must be installed by an electrical contractor and approved by a local building / electrical inspec- tor.

RCD and Wiring Requirements

The power supplied to the spa must be on a dedi- cated RCD protected circuit with no other appliances or lights sharing the power.

Use copper wire with THHN insulation. Do not use aluminum wire.

Use the table on the next page to determine your GFCI and wiring requirements.

When wires larger than #6 AWG are required, install a junction box near the spa and use #6 AWG wire between the junction box and the spa.

Wire runs over 85 feet must increase wire gauge to the next lower num- ber. For example: A normal 50 amp RCD with four #8 AWG copper wires run over 85 feet would require you to go to four #6 AWG copper wires.

Testing the RCD Breaker

Test the RCD breaker prior to first use and periodically when the spa is powered. To test the RCD breaker follow these instructions (spa should be operating):

1.Press the TEST button on the RCD. The RCD will trip and the spa will shut off.

2.Reset the RCD breaker by switching the breaker to the full OFF posi- tion, wait a moment, then turn the breaker back on. The spa should have power again.