Operating Instructions and Parts Manual

Pre-Operation (Continued)

1-3/8 inch [3.5 cm or 35 mm]

 

GROUNDING

 

 

 

 

1. Use the ground terminal and

 

 

 

 

 

 

 

 

wing nut on the generator frame

 

 

 

 

to connect the unit to a suitable

 

 

 

 

ground source. Securely fasten

 

 

 

 

the end terminal of the ground

 

 

 

 

wire to the ground terminal on

 

 

 

 

the generators frame. Tighten the

 

 

Gasoline Fill Level

washer and wing nut on top of the

 

 

ground wire end terminal.

 

 

 

 

Figure 1

2.The ground wire should be made

of #8 gauge wire. Do not use wire

FUELING AND REFUELING

6.

After each start up, allow the

with a higher gauge number.

(SEE FIGURE 1)

 

 

 

engine to run for 2-3 minutes with

Higher gauge numbers indicate

1.

Shut-off engine and wait 2 minutes

 

 

no load.

 

thinner wire, which may not

 

 

before filling fuel tank.

 

 

 

 

 

Engine speed is

 

 

 

 

 

 

 

provide an adequate ground path.

2.

 

Remove fuel cap and fill fuel tank

 

 

 

 

 

preset to provide

 

 

 

 

 

 

3. The other end of the ground wire

 

proper output voltage. Never attempt

 

 

to bottom of metal filler neck;

 

 

to modify or adjust engine speed or

must be securely fastened to an

 

 

about 1-3/8 inch [3.5 cm or 35 mm]

 

 

output voltage.

 

approved ground source.

 

 

 

from top of filler neck opening.

 

 

 

 

 

 

 

 

 

 

 

The following are ground sources

3.

Do not overfill fuel tank. Overfilling

ENGINE BREAK-IN

 

approved by the National Electric

 

 

may damage roll-over valve and

After initial start-up, the engine

Code. Other ground sources may be

 

 

carbon canister.

 

should be broken in according to the

acceptable. Refer to the National

4.

 

Reinstall fuel cap; make sure to

manufacturer's instructions. Refer to the

Electric Code and local regulations for

 

engine manual for the proper break-in

 

 

rotate cap clockwise unit it stops.

further ground source information. If

 

 

procedure.

 

 

 

 

 

 

 

not sure of regulations or procedures,

STARTING

 

SHUT-OFF

 

obtain assistance from a qualified

 

 

1.

 

Remove all electrical loads from the

 

(licensed or certified) electrical

 

 

1.

Shut off and remove all electrical

 

 

 

generators.

 

technician.

 

 

 

 

 

 

 

load devices from the generator.

 

 

2.

 

Rotate fuel petcock valve lever,

 

 

a. An underground water pipe at

 

2.

Allow the engine to run for 2-3

 

 

located on underside of fuel tank,

least ten feet in length

 

 

 

 

 

minutes with no electrical loads.

 

 

 

to the vertical position to open

 

 

b. A non-corrosive underground

 

 

3.

Flip the engine toggle switch (on

 

 

valve.

 

pipe at least eight feet in length

 

 

 

3.

Flip engine toggle switch (on

 

 

control panel) to the OFF position.

and 3/4 inch diameter

 

 

 

 

4.

Verify that the generator has

c. A steel or iron underground rod

 

 

control panel) to the ON position.

at least eight feet in length and

4.

The engine is equipped with an

 

 

completely stopped.

 

5.

Rotate fuel petcock valve lever,

5/8 inch diameter

 

 

 

automatic choke. However, the

d. A non-ferrous rod at least

 

 

choke mechanism has a manual

 

 

located on underside of fuel tank,

eight feet in length, 1/2 inch

 

 

override feature for extreme cold

 

 

to the horizontal position to close

in diameter, and approved for

 

 

weather starting. For extreme cold

 

 

valve.

 

grounding purposes

 

 

 

weather starting, pull choke wire;

6.

Allow the unit to cool before

Any rod or pipe used for grounding

 

 

after engine warms, push choke in

 

 

installing any covers.

 

must be driven to eight feet deep or

 

 

to it's normal operating position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

buried in the deepest possible trench.

5.

Pull the starter rope with a brisk,

 

 

 

 

 

 

 

 

 

 

 

 

smooth motion.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 1 - ESTIMATED POWER USAGE (WATTS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOAD DEVICE

WATTS

LOAD DEVICE

WATTS

LOAD DEVICE

WATTS

LOAD DEVICE

WATTS

Air conditioner

2000-3000

Electric drill

 

 

500-1000

 

Radio

50-200

 

Toaster

900-1700

 

 

(large)

 

 

 

 

 

 

 

 

 

 

 

 

Automatic

150-1500

Fan

 

 

40-200

 

Refrigerator

190-2000

Vacuum cleaner

200-300

washer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brooder

100+

Freezer

 

 

300-500

 

Skillet

1200

 

Water pump

1000-3000

Clothes dryer

5000-10,000

Hot plate

 

 

330-1100

 

Space heater

600-4800

Water heater

1000-5000

Coffee maker

400-700

Iron

 

 

500-1500

 

Sump pump

400-3000

Small hand saw

1000-2000

Electric drill

225-1000

Light bulb

 

 

AS RATED

 

Television

200-500

Large hand saw

1500-2500

(small)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 