Section 3. ET Instrumentation Installation
3.3.3.1 Internal Installation
For installation inside the ET Enclosure, the following components are provided in the
(1)SC932C Interface
(1)Rad Modem
(1)Rad/SC932C Mounting Bracket
(4)Screws
(1)12 inch
Install the
1.Mount the Rad / SC932C mounting bracket into the ET Enclosure with the 3
2.Connect the Rad Modem and SC932C. Strap them into the mounting bracket under the Velcro strap.
3.Connect the SC932C
4.Wire the Rad Modem to the ET Enclosure with the
3.3.3.2External Installation
The following
At the ET Enclosure:
(1)20 foot
(2)2 Direct Bury Splice Kits
(1)Length of User Supplied Wire (Supplier: Anixter, p/n
At the PC:
(1) Rad Modem
(1) 5 foot
(1)10 foot 14 AWG Ground Wire
(1)Surge Protector and Case
1)Connect the 20 foot patch cable to connector #8 on the external back panel of the ET Enclosure. Splice this cable to the user supplied cable, using the direct bury splice kits.
2)Mount the surge protector to a flat surface within 10 inches of the PC's serial port. Ground the center terminal to an earth (or building) ground using the 14 AWG wire.