Section 4. ET106 Sensor Arm Installation
4.4 034A Wind Sensor Installation
Install the 034A Wind Sensor as shown in Figure
FIGURE
1)Place the 034A in the 034A Mounting Shaft pointing the vane due south. Tighten the alignment screw.
2)Attach the 034A and mounting shaft to the sensor arm. Insert the mounting shaft into the
3)Attach the 034A connector to the 034A.
4)Establish a reference point on the horizon for True North.
5)Sighting down the instrument center line, aim the counter weight at True North. Display input location #8 (Section 4.6) for wind direction using the *6 Mode of the datalogger, or the Monitor Mode of PC208.