RF400 Series Spread Spectrum Data Radio/Modems

Main Menu

SW Version 6.425 (for example)

(1)Standard Setup

(2)Advanced Setup

(3)Restore Defaults

(4)Show All Current and Default Settings

(5)Save All Parameters and Exit Setup

(9)Exit Setup without Saving Parameters Enter Choice:

4.Press “1” for Standard Setup Display:

Standard Setup:

Current Setting

(1)

Active Interface

Auto Sense

(2)

Net Address

0

(3)

Radio Address

1

 

(Net + Radio Address 0h)

(4)

Hopping Sequence

0

(5)

Standby Mode

< 4 mA, ½ sec Cycle

(6)

Retry Level

 

(9)Return to Main Menu Enter Choice:

a.Leave Active Interface in “Auto Sense” (default setting) for most applications. In Auto Sense the RF400 will test for 5 V on CS I/O port (pin 1) to determine if a datalogger is present and if so select the CS I/O port.

b.Select a Net Address from (0 – 63). Unless there is a neighboring network, leave network address “0.” The Network Address must be the same throughout the network of RF400s.

22