c.Select a Radio Address (0 – 1023). The radio addresses must be the same in point-to-point communications (for point-to-multipoint communications you could set the base RF400 to 0 and the remotes to 1, 2, 3, etc.).

It is a good idea to label each RF400 indicating the configured network address, radio address, hopping sequence, etc.

d.Select a Hopping Sequence (0 – 6). The hopping sequence must be the same for all RF400s in the network.

If there happens to be a neighboring RF400 network using the same hopping sequence, you should change to a different one in case their network and radio addresses happen to match yours and to reduce retries.

- RX LED Test -

To determine if there is a neighboring RF400 network in operation using the same hopping sequence as yours, stop communications on your network and observe an RF400 green LED for activity. A flashing green LED would indicate that there is a nearby network using the same hopping sequence.

e.Select desired Standby mode (< 24 mA Always on, < 4 mA ½ sec Cycle, etc.) according to your power budget. All RF400s in the network must be in the same Standby Mode. The default setting is a good starting point (< 4 mA ½ sec Cycle).

f.Select desired Retry Level (None, Low, Medium or High) according to the level of RF ‘collisions’ you expect. This depends on how many neighboring RF400s in and out of your network and the frequency of transmissions. Retries can, for example, reduce pauses in real-time monitoring of Input Locations.

g.Press 9 to “Return to Main Menu”.

h.There are other (“advanced”) parameters which typically remain “default” or as set by Auto Sense.

i.Press “5” to “Save All Parameters and Exit Setup.”

5.3.2Remote Station Setup

1.Point-to-point

a.Complete steps 1 to 4 above making the remote station’s Network Address, Radio Address, and Hopping Sequence the same as the base station’s.

b.While in Standard Setup verify that the Active Interface configuration is “Auto Sense” and set the Standby Mode the same as the base RF400 (default “2” ok).

c.Exit and Save your configuration by pressing “5”.

23