Appendix L. RF400/RF410 Average Current Drain Calculations
EXAMPLE #6 (Base RF400/RF410 in “<0.4 mA, 8 sec Delay” standby mode)
The RF400/RF410s in this example are configured for the lowest possible average standby mode current (Advanced Setup Menu selection 7). The same amount of data are collected as in Example 1, however the frequency of collection is changed from once a minute to once an hour.
It = Is + Ih + Iq + Ir + Ii
Calculating each term:
Is = table mA value = 0.4 mA
Ih = |
| L (ms) | ⋅ 73 mA = | 8200 ms | ⋅ 73 mA = .17 mA ("long header"length = 8200 ms) | |||||
|
| 3,600,000 ms | ||||||||
|
| T (ms) |
|
|
|
|
| |||
Iq = |
| 20 (ms) | ⋅ 73 mA = 0.0004 mA |
| ||||||
| 3,600,000 (ms) |
| ||||||||
Ir = | [45 (ms) + 20 ms] |
| ⋅ 24 mA = 0.0004 mA |
| ||||||
| 3,600,000 (ms) |
| ||||||||
|
|
|
|
|
| |||||
Ii = |
| 5000 ms |
| ⋅ | 24 mA = 0.033 mA | (using default "time of inactivity to sleep" = 50) | ||||
3,600,000 (ms) |