Appendix I. Phone to RF400 Series
Where a phone to RF400 Base is desired, the following configurations will provide
1.HARDWARE REQUIREMENTS
a.RF400s
b.COM210
c.PS512M (or CH512R and battery)
(have
d.AC charger (CSI Item # 9591) or solar panel
e.Two SC12 cables (one included with RF400 and one with COM210)
2.
LoggerNet SETUP
a.Setup:
ComPort_1 PhoneBase
PhoneRemote RF400
RF400Remote
CR10X
b.ComPort_1 – default settings
c.PhoneBase
1) Maximum Baud Rate – 9600
2). Modem Pick List – per PC’s phone modem
3)Extra Response Time – 0 s
d.PhoneRemote – input base site’s phone number
e.RF400 – make Attention Character:
f.RF400Remote – Radio Address: “0” ; leave the rest defaults
g.CR10X – default settings, schedule collections as desired
PC208W SETUP
a.Device Map
COM1
Modem1
CR10X1
b.COM port - Default settings