Appendix I. Phone to RF400 Series

c.Phone Modem

1)Baud Rate – 9600

2)Modem Pick List – per PC’s phone modem

3)Extra Response Time – 2000 ms

d.Datalogger – Dialed Using Phone # at Base site

RF400 CONFIGURATION

a.Base RF400

1)Active Interface: “COM2xx to RF400”

2)AT Command (Attention) Character: “-“

3)All other settings: defaults

b.Remote RF400 – leave all settings: defaults

Note: If there is a neighboring RF400 network, you should change the Hopping Sequence of base and remote RF400s to a new setting to avoid interference (see Section 5.3.1 for method to detect neighboring network).

3.POINT-TO-MULTIPOINT COMMUNICATIONS

PC-Modem ------------ COM210-PS512M-RF400------------ RF400-DL1

(null-modem) ------------ RF400-DL2

LoggerNet SETUP

a.Setup:

ComPort_1 PhoneBase

PhoneRemote RF400

RF400Remote

CR10X

RF400Remote_2

CR10X_2

b.ComPort_1 – default settings

c.PhoneBase

1)Maximum Baud Rate – 9600

2)Modem Pick List – per PC’s phone modem

3)Extra Response Time – 0 s

d.PhoneRemote – input base site’s phone number

e.RF400 – make Attention Character: “-“ ; leave the rest defaults

f.RF400Remote – make Radio Address: “1“ ; leave the rest defaults

g.RF400Remote_2 – make Radio Address: “2“ ; leave the rest defaults

h.Dataloggers – default settings, schedule collections as desired

I-2