When the documents overlap by less than 2.0" (50 mm) or are stuck together due to static electricity, double-feeding may not be able to be detected correctly using ultrasonic.
DR-2010C //DR-2510C
This detection method is effective when scanning documents of different sizes. It uses ultrasonic waves to detect the gap between documents when more than two sheets of paper are fed at the same time. Feeding is stopped when a double-feed is detected.
Rapid System Recovery

This section describes the procedure for setting the system recovery method used by the scanner when document feeding stops due to a paper jam or other error during scanning.

1In the ISIS/TWAIN driver properties dialog box, click the [Others] tab select the [Rapid recovery system] check box click [OK].

NOTE

If you select [Rapid recovery system] and a paper jam or other error causes document feeding to stop while scanning, scanning stops without sending an error notification to the application program. After you clear the paper jam or resolve the error, you can resume the normal scanning operations.

Contents

Back

 

Previous Page Next Page

Double Feed Detection

This section describes the procedure for setting the scanner to stop document feeding when double feeding of document pages is detected.

1Click the [Others] tab select the [Detect by Length] or [Detect by Ultrasonic] (for the DR-2510C only) check box under [Double Feed Detection click [OK].

NOTE

Details of each detection method are indicated below.

[Detect by Length]

This detection method is effective when scanning documents of the same size. It detects double-feeding when a document is 2.0" (50 mm) longer or 2.0" (50)

mmshorter than the standard length (the length of the first document). Feeding is stopped when a double-feed is detected.

[Detect by Ultrasonic]

The two detection methods can be used at the same time.

51