infinity Furnace | infinityHP/AC |
Board | Board |
OutdoorAir Thermistor
(Suppliedwith IU)
FIELD CONNECTION
REQUIRED (BLACKWIRES)
Standard
4=Wire
Thermostat
OutdoorCoil Thermistor
FACTORYCONNECTED
_'m m
FACTORYWIRESPROVIDED
FOR FIELDCONNECTION
OFUTiLiTY CURTAILMENT
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| AO6302 |
|
| Fig. 22 - | Emergency | Cooling/Heating |
| Wiring | Connections |
|
|
|
| |||||
| Required Subcooling °F (°C) |
|
|
|
| Required Liquid Line Temperature for a Specific Subcooling |
| |||||||||
|
| Outdoor Ambient Temperature |
|
| Required Subeoolin9 (°F) |
|
| Required Subcooling (°C) |
| |||||||
Model Size |
|
|
|
|
| Pressure |
|
|
|
| Pressure |
|
|
| ||
024 | 15.5(8.6) | 15.6(8.7)15.7(8.7)15.8(8.8)15.9(8.9) |
|
| 174 | 56 | 5I | 46 | 36 | 1200 | 13 | I1 | 8 | 2 | ||
030 | 16.8(93) | 16,4(9.I) | I6.2(9) | 156(8,7) |
| 15(8,3) | I81 | 59 | 54 | 49 | 39 | 1248 | 15 | I2 | 9 | 4 |
036 | 14(7.7) | 13.9(7.7) | 13.9(7.7) | 13.8(7.7) | 13.7(7.6) | 188 | 61 | 56 | 51 | 41 | 1296 | 16 | 13 | 10 | 5 | |
042 | 19.2( 10.7 ) | 19.1 ( 10.6 ) | 19.1( 10.6 ) | 18.9 ( 10.5) | 18.7( 10.4 ) | 195 | 63 | 58 | 53 | 43 | 1344 | 17 | 14 | 12 | 6 | |
048 | 21(11.6) | 20.8(11.5) | 20,7(11.5) | 20,4(11,3) | 20.2(11.2) | 202 | 65 | 60 | 55 | 45 | 1393 | 18 | 16 | 13 | 7 | |
oe° | 16.2(9) | 16.6(9.2) | 16.8(9.3) | 17.3(9.6) | 17.8(9.9) | 209 | 67 | 62 | 57 | 47 | 1441 | 20 | 17 | 14 | 9 | |
|
|
|
|
|
|
| 216 | 69 | 64 | 59 | 49 | 1489 | 2I | 18 | 15 | 10 |
|
|
|
|
|
|
| 223 | 71 | 66 | 61 | 51 | 1537 | 22 | 19 | 16 | 11 |
Char in | Procedure |
|
|
|
|
| 230 | 73 | 68 | 63 | 53 | 1586 | 23 | 20 | 17 | 12 |
1- MeasureDischargeline pressurebyattachinga gaugeto theservice port. |
| 237 | 75 | 70 | 65 | 55 | I834 | 24 | 21 | I9 | I3 | |||||
2- Measurethe Liquid linetemperatureby attachingatemperaturesensingdevice to it, | 244 | 77 | 72 | 67 | 57 | 1882 | 25 | 22 | 20 | 14 | ||||||
3- insulatethe temperaturesensing deviceso that theOutdoor Ambient doesn'taffect |
|
|
|
|
|
|
|
|
|
| ||||||
the reading, |
|
|
|
|
| 259 | 81 | 76 | 71 | 61 | 1786 | 27 | 24 | 22 | 16 | |
4- Referto the required Subcooiingin thetable basedon themodel size and the | 267 | 83 | 78 | 73 | 63 | 1841 | 28 | 26 | 23 | 17 | ||||||
|
|
|
|
|
|
| 275 | 85 | 80 | 75 | 65 | 1896 | 29 | 27 | 24 | 18 |
OutdoorAmbient temperature. |
|
|
|
|
| 283 | 87 | 82 | 77 | 67 | 1951 | 31 | 28 | 25 | 19 | |
5- Interpolateif theOutdoortemperaturelies in betweenthetable values, Extrapolateif | 291 | 89 | 84 | 79 | 69 | 2008 | 32 | 29 | 28 | 20 | ||||||
the temperaturelies beyondthe table range. |
|
|
|
| 299 | 91 | 86 | 81 | 71 | 2061 | 33 | 30 | 27 | 22 | ||
6- Findthe PressureValue correspondingto the themeasured Pressureon the | 308 | 93 | 88 | 83 | 73 | 2123 | 34 | 31 | 28 | 23 | ||||||
CompressorDischargeline. |
|
|
|
|
| 317 | 95 | 90 | 85 | 75 | 2185 | 35 | 32 | 29 | 24 | |
|
|
|
|
|
|
| ||||||||||
7- Readacrossfrom the Pressure readingto obtainthe Liquid linetemperaturefor a | 326 | 97 | 92 | 87 | 77 | 2247 | 36 | 33 | 30 | 25 | ||||||
required SubcooIing. |
|
|
|
|
| 335 | 99 | 94 | 89 | 79 | 2309 | 37 | 34 | 31 | 26 | |
8- Add Charge if the measuredtemperatureis higherthan theliquid line temperature | 344 | 101 | 96 | 9I | 81 | 2372 | 38 | 35 | 33 | 27 | ||||||
valuein the table. |
|
|
|
|
| 353 | 102 | 97 | 92 | 82 | 2434 | 39 | 36 | 34 | 28 | |
9- Add Charge usingthe serviceconnection on the Suctionline of the Compressor, | 363 | 104 | 99 | 94 | 84 | 2503 | 40 | 37 | 35 | 29 | ||||||
|
|
|
|
|
|
| 373 | 106 | 101 | 96 | 86 | 2571 | 41 | 39 | 36 | 30 |
|
|
|
|
|
|
| 383 | 108 | 103 | 98 | 88 | 2640 | 42 | 40 | 37 | 31 |
|
|
|
|
|
|
| 393 | 110 | 105 | 100 | 90 | 2709 | 43 | 4I | 38 | 32 |
|
|
|
|
|
|
| 403 | 112 | 107 | 102 | 92 | 2778 | 44 | 42 | 39 | 33 |
|
|
|
|
|
|
| 413 | 114 | 109 | 104 | 94 | 2847 | 45 | 43 | 40 | 34 |
|
|
|
|
|
|
| 423 | 116 | 111 | 106 | 96 | 2916 | 46 | 44 | 41 | 35 |
|
|
|
|
|
|
| 433 | 117 | 112 | 107 | 97 | 2985 | 47 | 45 | 42 | 36 |
|
|
|
|
|
|
| 443 | 119 | 114 | 109 | 99 | 3054 | 48 | 46 | 43 | 37 |
|
|
|
|
|
|
| 453 | 121 | 116 | 111 | 101 | 3123 | 49 | 47 | 44 | 38 |
|
|
|
|
|
|
| 463 | I22 | 117 | 112 | 102 | 3192 | 50 | 47 | 45 | 39 |
|
|
|
|
|
|
| 473 | 124 | 119 | 114 | 104 | 3261 | 51 | 48 | 46 | 40 |
|
|
|
|
|
|
| 483 | 126 | 121 | 116 | 106 | 3330 | 52 | 49 | 47 | 41 |
|
|
|
|
|
|
| 493 | 127 | 122 | 117 | 107 | 3399 | 53 | 50 | 47 | 42 |
|
|
|
|
|
|
| 503 | 129 | 124 | 119 | 109 | 3468 | 54 | 51 | 48 | 43 |
|
|
|
|
|
|
| 513 | 130 | 125 | 120 | 110 | 3537 | 55 | 52 | 49 | 44 |
|
|
|
|
|
|
| 523 | 132 | 127 | 122 | 112 | 3606 | 56 | 53 | 50 | 44 |
|
|
|
|
|
|
| 533 | 133 | 128 | 123 | 113 | 3675 | 56 | 54 | 51 | 45 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 50DU500166- 2,0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| AO8423 |
|
|
|
| Fig. 23 | - | Cooling | Charging |
|
|
|
|
|
|
27