Troubleshooting
Install
Typical PremierLink Wiring Schematic
Configure the Unit for Thermostat Mode
Economizer Wiring
Controller Assembly
Input Signal
Heat Anticipator Settings
Supply Air Temperature SAT Sensor
Weight
Page 18
Image 18
50HCQA
Fig. 30 - Typical PremierLink Wiring Schematic
C10227
18
Page 17
Page 19
Page 18
Image 18
Page 17
Page 19
Contents
50HCQA Single Package Rooftop Heat Pump
TABLE OF CONTENTS
Installation Instructions
with Puronr R---410ARefrigerant Sizes
50HCQA
SAFETY CONSIDERATIONS
UNIT OPERATION AND SAFETY HAZARD
ELECTRICAL SHOCK HAZARD
Horizontal Connections / Economizer
50HCQA
Vertical Connections / Economizer
C10230
Jobsite Survey
INSTALLATION
Fig. 2 - Service Clearance Dimensional Drawing
Step 1 - Plan for Unit Location
Pad-mountedinstallation
Step 2 - Plan for Sequence of Unit Installation
Curb-mountedinstallation
Frame-mountedinstallation
Fig. 3 - Roof Curb Details
50HCQA
Step 6 - Rig and Place Unit
For Units with Accessory Electric Heaters
Step 5 - Field Fabricate Ductwork
Fig. 4 - Unit Leveling Tolerances
Fig. 5 - Rigging Details Positioning on Curb
Fig. 6 - Horizontal Conversion Panels
50HCQA
Fig. 7 - Typical Access Panel Locations
Step 8 - Install Outside Air Hood
Economizer Hood Removal and Setup
Fig. 8 - Economizer Wiring
Economizer Hood and Two-PositionHood
Fig. 12 - Economizer Filter Installation
Fig. 10 - Indoor Coil Access Panel Relocation
Fig. 11 - Economizer Hood Construction
Units Without Factory-InstalledDisconnect
Field Power Supply
Fig. 15 - Disconnect Switch and Unit
Step 10 - Make Electrical Connections
Units Without Disconnect Option
Units with Factory-InstalledDisconnect
Fig. 16 - Power Wiring Connections
Units With Disconnect Option
Factory-Option Thru-BaseConnections
Fig. 18 - Weatherproof Cover Installation
Fig. 19 - Powered Convenience Outlet Wiring
50HCQA
Heat Anticipator Settings
Field Control Wiring
Unit without Thru-BaseConnection Kit
Fig. 20 - Thru-BaseConnection Fittings
Electric Heaters
Fig. 22 - Field Control Wiring Raceway
Fig. 23 - Typical Access Panel Location
Table 2 - Heater Model Number
Single Point Boxes and Supplementary Fuse
Fig. 25 - Typical Module Installation
Fig. 26 - Typical Single Point Installation
50HCQA
Fig. 28 - PremierLink Controller
Supply Air Temperature SAT Sensor
PremierLinkt Factory-Option
50HCQA
Fig. 30 - Typical PremierLink Wiring Schematic
50HCQA
C10227
Fig. 31 - T-55Space Temperature Sensor Wiring
Outdoor Air Temperature OAT Sensor
Space Temperature SPT Sensors
Field Connections
G2 J4-12 Y1 4 J4-10 Y2 6 J4-8 W1 8 J4-6
SPACECTB THERMOSTAT THERMOSTAT R R
TB1PL
J4-4
INPUT SIGNAL
Table 4 - Space Sensor Mode
Table 5 - Thermostat Mode
INPUT SIGNAL
Fig. 36 - Enthalpy Switch 33CSENTHSW Connections
Configure the Unit for Thermostat Mode
Wiring
Economizer Controls
PNO 33ZCSENCO2 plus weatherproof enclosure
33ZCSENCO2 - Typical Wiring Diagram
Outdoor Air Quality Sensor
Fig. 38 - Indoor/Outdoor Air Quality CO2 Sensor
Supply Fan Status Switch
Filter Status Switch
Fig. 42 - PremierLink Filter Switch Connection
Fig. 43 - PremierLink Wiring Fan Pressure Switch
Table 7 - Color Code Recommendations
Connecting CCN bus
Table 6 - Recommended Cables
Fig. 46 - PremierLink CCN Bus Connections
Fig. 48 - 50HCQ Control Box Component Locations
RTU-MPControl System
Fig. 47 - RTU-MP Multi-ProtocolControl Board
50HCQA
50HCQA
C10229
Outdoor Air Temperature OAT Sensor
Table 8 - RTU-MPController Inputs and Outputs
Supply Air Temperature SAT Sensor
50HCQA
Fig. 50 - RTU-MP T-55Sensor Connections
Fig. 52 - Space Temperature Sensor Typical Wiring
33ZCT59SPT
Fig. 51 - RTU-MP T-56Sensor Connections C08461
33ZCSENCO2 Connections
Connecting Discrete Inputs
Fig. 53 - RTU-MP /Indoor CO2 Sensor
Fig. 54 - RTU-MP /Outdoor CO2 Sensor
Fig. 56 - RTU-MPSW3 Dip Switch Settings
Communication Wiring - Protocols
Fig. 55 - RTU-MPPower Exhaust Connections
General
Fig. 57 - BACview6 Handheld Connections
Local Access
RTU-MPTroubleshooting
50HCQA
System
Smoke Detectors
Table 9 - LEDs
Controller
Supply Air
Fig. 58 - Controller Assembly
Smoke Detector Locations
Location Return Air without Economizer
Return Air
See “Completing Installation of Return Air Smoke
Flexible Exhaust Tube
Sampling Tube
HIGH
50HCQA
NOTE See page 42 for table legend and notes
HIGH
DD---STD
50HCQA
UNIT
HIGH
HIGH
50HCQA
DD---STD
HIGH
208/230
50HCQA
UNIT
HIGH
208/230
50HCQA
UNIT
HIGH
HIGH
50HCQA
208/230
HIGH
EconoMi$er IV Occupancy Switch
Step 11 - Adjust Factory-InstalledOptions
Fig. 65 - EconoMi$ert IV Wiring
Legend and Notes for Table
Step 12 - Install Accessories
Pre-Startand Start-Up
50HCQA
Edition Date 04/10
50HCQA
Catalog No 50HCQ---01SI
Replaces NEW