Carrier 50PCH specifications a50-8696, 50PCV Unit Dimensions, 50PCV006-060UNITS

Models: 50PCH

1 52
Download 52 pages 49.25 Kb
Page 6
Image 6
a50-8696

P

N

FIELD INSTALLED

ACCESS PANELS

DISCHARGE FLANGE

 

O

Q AIR COIL AND FRONT SIDE

TOP VIEW-FRONT RETURN

 

P

N

O

FRONT

 

 

 

Q

AIR COIL SIDE

 

TOP VIEW-RIGHT RETURN

LEGEND

ASP — Alternate Service Panel

BSP — Blower Service Panel

CAP — Control Access Panel

CSP — Compressor Service Panel

FPT — Female Pipe Thread

HV — High Voltage

LV — Low Voltage

 

B

 

 

N

P

 

 

 

 

FRONT

O

 

 

 

 

 

 

A

 

AIR COIL SIDE

 

M

 

 

 

TOP VIEW-LEFT RETURN

STANDARD FILTER BRACKET

AIR COIL50PCV006-060 UNITS

BSP

CSP

CAP

ASP

OPTIONAL

2 FT [610 MM]

SERVICE

ACCESS

LEFT RTN

(RIGHT RTN OPPOSITE SIDE)

RS

U Fig. 3 — 50PCV Unit Dimensions

T

C

CSP

FRONT Manual background

RIGHT RETURN RIGHT VIEW

- AIR COIL OPENING

 

S

R

 

 

ISOMETRIC

 

 

 

 

2 FT [610 MM]

 

 

 

 

 

 

SERVICE

 

VIEW

 

 

 

 

U

 

 

 

 

 

 

 

1.00 [25.4 MM]

 

 

 

 

 

 

 

 

 

AIR COIL

 

AIR COIL

 

 

 

 

 

 

 

 

T

a50-8696

 

 

BSP

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

CONDENSATE

 

 

POWER SUPPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/4" FPT

 

 

3/4" [19.1 MM] HV

 

 

 

 

 

 

 

 

 

KNOCKOUT

 

 

 

2

 

 

 

 

 

LOW VOLTAGE

 

CAP

 

 

 

 

 

1/2" [12.7 MM] LV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KNOCKOUT

 

 

 

 

 

 

 

 

CSP

LOW VOLTAGE

 

 

 

3

 

 

F

 

1/2" [12.7 MM] LV

 

 

L

 

 

 

 

KNOCKOUT

 

K

 

 

 

I

 

BACK

BACK

FRONT

 

 

 

 

H

CSP

J

 

 

 

 

 

1

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

LEFT RETURN LEFT VIEW

 

 

FRONT-VIEW

E

 

 

 

- AIR COIL OPENING

 

 

 

 

 

 

 

 

 

 

50PCV006-060 UNITS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DISCHARGE CONNECTION

RETURN CONNECTION

 

 

 

OVERALL CABINET

 

 

WATER CONNECTIONS

 

ELECTRICAL KNOCKOUTS

DUCT FLANGE INSTALLED

USING RETURN AIR

50PCV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(±0.10 in., ±2.5 mm)

 

 

OPENING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

K

L

 

 

 

 

 

 

 

 

 

UNIT

 

 

 

 

 

1

 

2

 

 

3

 

 

1/2-in.

1/2-in.

3/4-in.

 

 

O

P

 

 

S

T

 

SIZE

 

A

B

C

 

 

 

 

 

 

 

 

Size

(1.3 cm)

(1.3 cm)

(1.3 cm)

 

 

 

 

 

 

 

 

Width

Depth

Height

 

 

 

 

 

 

 

 

(IPT)

 

 

 

M

N

Supply

Supply

Q

R

Return

Return

U

 

 

 

D

E

 

F

G

 

 

 

Low

Low

Power

 

 

Width

Depth

 

 

Depth

Height

 

 

 

 

 

 

 

 

H

 

I

 

 

 

 

 

 

 

 

 

 

 

 

Loop In

 

Loop Out

 

 

Voltage

Voltage

Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

006-

 

in.

19.1

19.1

22.0

1.4

1.6

 

9.5

1.6

6.1

 

1.6

1/2

2.9

5.9

8.9

8.9

5.1

9.0

9.0

5.5

2.1

16.2

9.9

0.7

012

 

cm

48.5

48.5

55.9

3.6

4.1

 

24.1

4.3

15.6

 

4.1

1.3

7.3

14.9

22.5

22.7

12.9

22.9

22.9

14.0

5.3

41.1

25.1

1.9

015

 

in.

21.5

21.5

39.0

1.9

1.4

 

13.8

1.4

8.1

 

1.4

1/2

4.1

7.1

10.1

6.4

3.8

14.0

14.0

5.3

2.3

18.3

20.9

0.7

 

cm

54.6

54.6

99.1

4.8

3.6

 

35.1

3.6

20.6

 

3.6

1.3

10.5

18.1

25.7

16.1

9.5

35.6

35.6

13.6

5.8

46.5

53.1

1.9

 

 

 

 

018

 

in.

21.5

21.5

39.0

1.9

1.4

 

12.9

1.4

8.1

 

1.4

1/2

4.1

7.1

10.1

6.4

3.8

14.0

14.0

5.3

2.3

18.3

20.9

0.7

 

cm

54.6

54.6

99.1

4.8

3.6

 

32.8

3.6

20.6

 

3.6

1.3

10.5

18.1

25.7

16.1

9.5

35.6

35.6

13.6

5.8

46.5

53.1

1.9

 

 

 

 

024

 

in.

21.5

21.5

40.0

1.9

1.4

 

13.8

1.4

8.1

 

1.4

3/4

4.1

7.1

10.1

6.4

3.8

14.0

14.0

5.3

2.3

18.3

20.9

0.7

 

cm

54.6

54.6

101.6

4.8

3.6

 

35.1

3.6

20.6

 

3.6

1.9

10.5

18.1

25.7

16.1

9.5

35.6

35.6

13.6

5.8

46.5

53.1

1.9

 

 

 

 

030

 

in.

21.5

21.5

40.0

1.9

1.4

 

15.2

1.4

8.1

 

1.4

3/4

4.1

7.1

10.1

6.4

3.8

14.0

14.0

5.3

2.3

18.3

20.9

0.7

 

cm

54.6

54.6

101.6

4.8

3.6

 

38.6

3.6

20.6

 

3.6

1.9

10.5

18.1

25.7

16.1

9.5

35.6

35.6

13.6

5.8

46.5

53.1

1.9

 

 

 

 

036

 

in.

21.5

26.0

45.0

1.9

1.4

 

15.7

1.4

8.1

 

1.4

3/4

4.1

7.1

10.1

6.4

3.8

14.0

14.0

5.1

2.3

22.8

23.9

0.7

 

cm

54.6

66.0

114.3

4.8

3.6

 

39.9

3.6

20.6

 

3.6

1.9

10.5

18.1

25.7

16.1

9.5

35.6

35.6

13.1

5.8

57.9

60.7

1.9

 

 

 

 

042

 

in.

21.5

26.0

45.0

1.9

1.4

 

16.6

1.4

8.1

 

1.4

3/4

4.1

7.1

10.1

6.4

3.8

14.0

14.0

5.1

2.3

22.8

23.9

0.7

 

cm

54.6

66.0

114.3

4.8

3.6

 

42.0

3.6

20.6

 

3.6

1.9

10.5

18.1

25.7

16.1

9.5

35.6

35.6

13.1

5.8

57.9

60.7

1.9

 

 

 

 

048

 

in.

24.0

32.5

46.0

1.9

1.4

 

16.6

1.4

8.1

 

1.4

1

4.1

7.1

10.1

6.9

7.3

16.0

18.0

5.1

2.3

29.3

22.5

0.7

 

cm

61.0

82.6

116.8

4.8

3.6

 

42.2

3.6

20.6

 

3.6

2.5

10.5

18.1

25.7

17.4

18.4

40.6

45.7

13.1

5.8

74.4

57.0

1.9

 

 

 

 

060

 

in.

24.0

32.5

46.0

1.9

1.4

 

16.7

1.4

8.1

 

1.4

1

4.1

7.1

10.1

6.9

7.3

16.0

18.0

5.1

2.3

29.3

22.5

0.7

 

cm

61.0

82.6

116.8

4.8

3.6

 

42.4

3.6

20.6

 

3.6

2.5

10.5

18.1

25.7

17.4

18.4

40.6

45.7

13.1

5.8

74.4

57.0

1.9

 

 

 

 

NOTES:

1.Shaded areas are recommended service areas. Installer should take care to comply with all building codes and allow adequate clearance for future field service.

2.Front and side access is preferred for service access. However, all components may be serviced from the front access panel if side access is not available except on 50PCV009- 030 with front return.

3.Discharge flange is field installed.

4.Condensate is 3/4 in. (19.1 mm) FPT.

5.Units shipped with filter rails. These rails should be removed for return duct connection. See WSHP Accessory Price Page for accessory air filter frame with duct collar.

Fig. 3 — 50PCV Unit Dimensions

6

Page 6
Image 6
Carrier 50PCH specifications a50-8696, 50PCV Unit Dimensions, 50PCV006-060UNITS