POWER SUPPLY
REFER TO DATA PLATE
USE COPPER CONDUCTORS ONLY.
SEE NOTE 2
REFER TO DISCONNECT
BOX FOR OPTIONAL
POWER SUPPLY CONNECTION
GROUND |
|
| NEUTRAL ON 265V |
| SYSTEMS |
L2 | RED |
2 | |
L1 | PB |
1 |
H |
|
| BLU | COMPRESSOR | |
|
| S | |||
CAP |
|
|
| ||
| 8 |
| R | ||
C RED 6 | RED | C | |||
F | 2 | CR |
|
| |
4 | BLK | ||||
BLK |
L2 (ribbed)
OPTIONAL |
| GROUND |
|
|
|
| BRN | 2 | B (HIGH) |
| ||
CORD |
|
|
|
|
|
| BM |
|
|
| ||
CONNECTION |
| L1 (plain) |
|
|
|
|
| YEL |
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||
| SEE |
|
|
| COM | NO | BLK | 1 | A (LOW) |
| ||
CB* |
|
|
|
| RED |
| ||||||
NOTE 3 | BLK |
|
| BLK |
|
|
| 2 |
| |||
| TRANS |
|
| BR |
| 1 | BLK |
| ||||
|
|
|
|
|
|
| FSS |
| ||||
24V |
| ORG |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||
|
| 230V |
|
|
|
|
|
|
|
|
|
|
|
|
| YEL | ORG |
|
|
|
|
|
| TRANSFORMER PRIMARY | |
|
| YEL | DM | BRN |
|
|
| SEE |
| LEAD COLORS | ||
|
|
|
|
|
|
|
|
|
| |||
| SEE |
| 1 | 0 |
| 1 | 0 |
| NOTE 7 | VOLTAGE | LEAD COLOR | |
| NOTE 7 | BR |
| CR |
|
|
| 115 | WHT | |||
|
|
|
|
|
|
|
|
| ||||
BLK TRANS | YEL | GRY | BRN | BRN BRN | YEL |
|
| 208 | RED | |||
| CB |
|
| 230 | ORG | |||||||
RED |
|
|
|
|
|
|
|
|
| |||
| BR | BRG | CCG |
|
|
|
|
| 265 | BRN | ||
(220V) | 24V | BLU |
| CC |
|
|
| |||||
|
|
|
|
|
|
|
|
| ||||
ORG (240V) |
| C |
|
|
|
|
|
|
|
|
|
|
| TYPICAL HEAT PUMP | BRN | YEL |
| TEST PINS | COMPR. |
|
|
|
| ||
| SEE NOTE 5 |
|
| R |
|
| HP 1 | RED | HP |
| ||
| CLASS 1 OR 2 | CLASS 1 WIRING |
| SEE | RELAY | RED |
| |||||
| WIRING ACCEPTABLE | REQUIRED INSIDE | Y |
| NOTE 4 | 2 |
|
| ||||
|
| 3 | BLU |
|
| |||||||
| OUTSIDE | CONTROL BOX |
|
| JW3 |
| LOC |
| ||||
| COMPRESSOR |
|
|
| LOC | BRN |
| |||||
| CONTROL BOX | Y |
| FP1 |
| 4 |
|
| ||||
| Y |
|
|
|
| JW2 |
| 5 | GRY |
|
| |
|
|
|
|
| W |
| FP2 |
| FP1 |
| ||
|
|
| COOLING |
|
| DIP SWITCH | FP1 | GRY | SEE |
| ||
| O |
|
| O |
| 6 |
| |||||
|
| FAN |
|
|
| 1 PM: DISABLED/ | 7 | VIO | NOTE 4 |
| ||
| G |
|
|
|
|
| ENABLED | FP2 |
| |||
|
|
|
| G |
|
| 2 STAGE 2: 2/1 | FP2 | VIO |
| ||
| R |
| 24 VAC |
|
|
| 8 |
|
| |||
|
|
| R |
|
| 3 NOT USED | RV 9 | BRN |
|
| ||
| C |
| COMMON |
|
|
| 4 NOT USED | RVS |
| |||
|
|
|
|
|
| ORG |
| |||||
|
|
|
| C |
|
| 5 FP1/FP2 | 10 |
|
| ||
| L |
| ALARM |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| AL1 | JW1 OFF ON FAULTS: 3/1 |
| NOT USED |
|
| |||
|
|
|
|
| AL2 |
|
| G STATUS | CO12 | YEL | CO |
|
|
|
|
|
| A | ALARM | SEE | LED | P2 |
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| RELAY | NOTE 6 | COMPLETE C | 24V |
|
|
| |
|
|
|
|
| P1 |
|
|
| ||||
| BRN |
|
| YEL |
|
| MICRO- | DC |
|
|
| |
| WV |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| PROCESSOR | EH1 |
|
|
| |
| GROUND |
|
|
|
|
|
| CONTROL |
|
|
| |
CAP |
|
|
|
|
|
| LOGIC | EH2 | BLOWER MOTOR WIRING | |||
PB |
|
|
|
|
|
| CO | P3 | ||||
|
|
|
|
|
|
|
| UNIT SIZE POLE A POLE B | ||||
|
| TRANSFORMER |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| 09 | 5 | 4 | |
|
| CR |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| 12 | 4 | 3 | |
|
|
|
|
|
|
|
|
|
| |||
|
| BR |
|
|
|
|
|
|
| 15 | 4 | 3 |
|
|
|
|
|
|
|
|
|
| 18 | 4 | 3 |
COMPLETE
C
CONTROL
|
| LEGEND |
AL | — | Alarm Relay Contacts |
BM | — | Blower Motor |
BR | — | Blower Relay |
CAP | — | Capacitor |
CB | — | Circuit Breaker |
CO | — | Sensor, Condensate Overflow |
CR | — | Compressor Relay |
DM | — | Damper Motor |
FP1 | — | Sensor, Water Coil Freeze Protection |
FP2 | — | Sensor, Air Coil Freeze Protection |
FSS | — | Fan Speed Switch |
HP | — | |
JW1 | — | Jumper Wire for Alarm |
LOC | — | Loss of Charge Pressure Switch |
PB | — | Power Terminal Block |
PM | — | Performance Monitor |
RVS | — | Reversing Valve Solenoid |
TRANS — | Transformer | |
WV | — | Water Valve |
Field Line Voltage Wiring | ||
|
| Field |
>>
Printed Circuit Trace
Option Low Voltage
Wiring
Relay/Contactor Coil
Solenoid Coil
Thermistor
Circuit Breaker
Relay
Ground
Wire Nut
*Optional wiring.
NOTES:
1.Compressor and blower motor thermally protected internally.
2.All wiring to the unit must comply with local codes.
3.Transformer is wired to
For 230/1/60 operation, switch the RED and ORG leads at L1 and insulate the RED lead.
Transformer is energy limiting or may have a circuit breaker.
4.FP1 thermistor provides freeze protection for WATER. When using
5.Typical heat pump thermostat wiring shown. Refer to thermostat Installation Instructions for wiring to the unit.
6.
7.Transformer secondary ground via Com- plete C board standoffs and screws to control box. (Ground available from top two standoffs as shown.)
Fig. 21 — 50PEC Unit Remote-Mounted Thermostat with Complete C Controller Wiring
22