START ASSIST

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

(WHEN NEEDED)

 

 

 

 

 

G/Y

 

 

POWER SUPPLY

EARTH (GRD)

5

 

RED*

BLU*

 

 

 

 

 

 

REFER TO

 

 

4

 

 

RED CAP BLU

 

 

DATA PLATE

 

 

3

YEL

 

S

 

USE COPPER

 

 

 

 

 

 

 

N (NEUTRAL)

 

RED

6

8

RED R

C

 

CONDUCTORS

2

 

 

 

2CR4

 

 

ONLY

 

L

1

BLK

 

 

 

 

 

 

 

COMPRESSOR

 

 

 

 

 

BLK

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

4

 

 

 

 

 

 

 

 

BR YEL CAPACITOR

 

 

 

 

 

 

6

8

BRN

 

 

 

 

 

 

YEL OR WHT

PSC

 

L(3)

 

 

 

 

 

 

 

FAN

 

M(2) BLU

 

 

 

 

 

 

 

MTR

 

H(1)

 

 

 

 

 

 

 

 

 

SEE NOTE 3

 

 

 

 

 

3 AIR FLOW SETTINGS

YEL CB* TRANS

 

 

 

 

 

BLK

 

 

 

 

(FCTRY SETTING - MED)

COMPONENT LOCATION

 

 

24V

RED

 

 

 

 

SEE NOTE 8

 

 

 

 

BLU

220V

 

 

 

 

 

G/Y

 

 

 

 

 

 

ORG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR

 

 

 

 

 

240V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SEE

 

 

 

 

 

 

 

 

 

 

 

CAP

 

 

NOTE 7

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR

 

 

 

 

 

 

 

BR

 

 

 

BR

 

 

 

 

 

 

 

 

 

 

 

GRY

 

 

BRN YEL

 

 

 

 

 

 

 

 

 

 

BRN

 

 

SEE

 

 

 

 

 

 

 

 

BR

BRG

CCG

CC

 

NOTE 7

 

 

 

 

 

 

 

 

 

 

 

 

 

PB

CXM

 

 

C

TEST PINS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SEE

 

R

 

 

 

COMPRESS.

1

RED

 

 

 

 

 

NOTE 5

 

 

 

 

RELAY

 

HP

 

 

 

 

 

 

 

 

HP

RED

 

 

 

 

TYPICAL

 

Y

 

 

 

 

 

2

 

 

 

TRANS

 

 

 

SEE

 

 

3

BLU

 

 

 

 

T-STAT

 

 

 

 

 

 

LOC

 

SIZES: 015-036

COMPR.

 

 

NOTE 4

 

 

LOC

BRN

 

 

Y

Y

 

 

 

4

 

 

 

 

 

JW3

 

DIP SWITCH

SEE NOTE 4

 

 

 

 

 

 

5

GRY

 

 

 

 

W

 

FP1

 

 

 

 

FP1

 

 

 

 

 

 

 

1

PM

FP1

 

 

 

 

 

O

COOLING

 

LOW TEMP

2

STAGE 2

6

GRY

(

TXV UNITS

)

 

 

 

O

 

JW2

 

3

NOT USED

7

VIO

 

 

 

 

 

 

 

 

NOT USED

 

 

 

 

 

G

FAN

 

 

FP2

 

4

1 OR 3

FP2

(CAP -TUBE VIO

FP2

 

 

 

 

G

 

LOW TEMP

5

TRIES

UNITS) OR

VIO

 

 

 

 

24 VAC

 

OFF

8

 

 

 

 

R

R

 

 

 

ON

9

BRN

 

 

 

 

 

 

 

 

 

 

 

 

RVS

 

 

 

C

COMMON

 

 

 

 

 

RV

ORG

 

 

 

 

ALARM

C

 

 

 

G

STATUS

10

 

 

 

 

 

L

AL1

JWI

 

LED

 

NOT USED

 

 

 

 

 

 

 

 

CO12

 

 

 

 

SEE NOTE 6 FOR

AL2

 

 

 

CXM

YEL

 

CO

 

 

 

SEE

 

P2

 

 

 

 

 

 

ALARM

 

 

 

 

 

 

DRY ALARM CONTACT

A

 

MICRO-

 

 

 

 

 

 

 

 

RELAY

NOTE

PROCESSOR

24V

 

 

 

 

 

 

 

 

PI

 

 

 

 

 

 

 

 

 

6

CONTROL LOGIC

DC

 

 

 

 

 

CR

 

 

 

 

 

 

 

 

 

PB

 

 

 

 

 

 

 

 

EH1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP

 

 

 

 

 

 

 

 

 

EH2

 

 

 

 

 

 

 

 

 

 

 

 

CO

P3

 

 

 

 

BR

 

 

 

 

 

 

 

 

 

 

 

 

 

CXM

 

 

 

 

 

 

 

 

 

 

 

 

 

TRANS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIZES: 006, 009, 012

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

AL

Alarm Relay Contacts

PM

Performance Monitor

 

 

 

 

 

 

Condensate Pan

 

 

BR

Blower Relay

PSC

Permanent Split Capacitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP

Compressor Capacitor

RVS

Reversing Valve Solenoid

 

 

Circuit Breaker

CB

Circuit Breaker

TRANS — Transformer Optional Wiring

 

CC

Compressor Contactor

 

 

 

Field Line Voltage Wiring

 

 

 

Relay Contacts — N.C.

 

 

 

 

CO

Sensor, Condensate Overflow

 

 

 

Field Low Voltage Wiring

Solenoid Coil

FP1

Sensor, Water Coil Freeze Protection

 

 

 

FP2

Sensor, Air Coil Freeze Protection

 

 

 

Printed Circuit Trace

 

 

Relay Contacts — N.O.

GND

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional Wiring

 

 

 

 

HP

High-Pressure Switch

 

 

 

Switch Temperature

 

 

 

 

 

 

 

 

 

 

 

JW

Clippable Field Selection Jumper

 

 

 

Relay/Contactor Coil

 

 

 

 

LOC

Loss of Charge Pressure Switch

 

 

 

 

 

 

 

 

 

 

 

Switch Low Pressure

P1

Field Wiring Terminal Block

 

 

 

Thermistor

Ground

PB

Power Block

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wire Nut

*Optional wiring.

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Compressor and blower motor thermally protected internally.

6. 24-v alarm signal shown. For dry alarm contact, cut JW1 jumper,

2. All wiring to the unit must comply with NEC and local codes.

 

and dry contact will be available between AL1 and AL2.

3. Transformer is wired to 240 v (ORG) lead for 240/50/1 units,

7. Transformer secondary ground via microprocessor board stand-

switch RED and ORG leads to PB(1) and insulate ORG lead.

offs and screws to control box. (Ground available from top two

4. FP1 thermistor provides freeze protection for water. When using

standoffs as shown.)

 

antifreeze solutions, cut JW3 jumper.

 

 

 

 

8. Fan motors factory wired for medium speed. For high or low

5. Typical heat pump thermostat wiring shown. Refer to thermostat

speed remove BLU wire from fan motor speed tap “M” and con-

installation instructions for wiring to the unit.

 

 

 

 

nect to “H” for high or “L” for low.

 

Fig. 9 — Typical Aquazone™ Complete C Control Wiring (Single-Phase Unit)