| PB |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 6 |
|
|
|
|
|
|
|
|
| G/Y |
|
|
|
|
| EARTH (GND) | 5 |
| G/Y |
|
|
|
|
| G/Y |
| ||
|
|
|
|
|
|
|
| GROUND |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| POWER SUPPLY | N (NEUTRAL) | 4 |
|
|
| LUG |
|
|
|
|
|
| ||
|
|
| REFER TO |
|
|
|
| BLK L3 | T3 |
| BLK |
|
|
|
| ||
|
|
| DATA PLATE |
| L3 | 3 |
|
|
| T3 |
|
| |||||
|
|
| USE COPPER |
|
| BLK L2CC T2 |
|
|
|
|
| ||||||
COMPONENT LOCATION |
| CONDUCTORS |
| L2 | 2 |
|
| BLK |
|
| T1 COMPR. | ||||||
|
|
| ONLY |
|
|
|
|
|
|
|
| T2 |
|
| |||
|
|
|
|
|
|
| BLK L1CC T1 |
| BLK |
|
|
| |||||
| LUG |
|
|
|
| L1 | 1 |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| T3 |
|
|
|
|
| BLK |
| BLK |
|
|
| BLK |
|
|
|
|
CC | T2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| T1 |
|
|
|
|
|
|
|
|
| YEL |
|
|
| BLK | BR2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| H | 8 | |||
|
|
|
| SEE NOTE 3 |
|
|
|
|
| YEL OR |
| BLU | 6 | ||||
|
|
|
|
|
|
|
|
| BM | M |
| ||||||
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
| CB* TRANS |
|
| BLK |
|
|
| WHT |
| L | RED | 7 |
| ||
| BR1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| RED |
|
|
|
|
|
| BRN |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| (220V) |
| ORG |
|
|
|
|
|
| SEE NOTE 8 | |||
| BR2 |
|
|
|
|
|
|
|
|
|
|
|
| ||||
PB |
|
|
|
|
|
| (240V) |
|
|
|
|
|
|
|
| ||
|
| SEE |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| NOTE 7 | 1 | BR 0 |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| CC |
|
|
|
|
|
|
|
|
| |||
| CXM |
|
|
| GRY | BRN | BRN | YEL |
|
| SEE |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
TRANS |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| BR | BRG | CCG | CC |
|
| NOTE 7 |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
| C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TEST PINS |
|
|
|
|
|
|
|
|
|
| |
|
|
|
| R |
|
| COMPRESSOR |
| 1 |
| RED |
|
|
|
| ||
|
|
|
|
|
|
| RELAY |
|
|
|
|
|
| ||||
| SEE NOTE 5 |
|
|
|
|
| HP 2 |
| RED |
|
| HP |
| ||||
| Y |
|
|
|
|
|
|
|
|
|
| ||||||
|
| TYPICAL |
|
|
|
|
|
|
| 3 |
| BLU |
|
|
|
| |
|
|
|
|
|
| SEE |
|
|
|
|
|
| LOC |
| |||
|
| COMPR. |
|
|
|
|
|
| LOC4 |
|
|
|
|
| |||
|
| Y | Y |
| NOTE 4 |
|
|
|
| BRN |
|
|
| ||||
|
|
|
| JW3 | DIP SWITCH |
| 5 |
| GRY |
|
| SEE NOTE 4 | |||||
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
| FP1 |
|
|
|
|
|
|
|
|
| ||
|
|
|
| W |
|
| 1 | PM |
| FP16 |
|
|
|
| FP1 |
| |
|
|
| COOLING |
| LOW TEMP | 2 | STAGE 2 |
|
| GRY |
|
|
| ||||
|
| O | O |
| JW2 |
| 3 | NOT USED |
|
| VIO |
|
| (TXV UNITS) | |||
|
|
|
|
| 4 | NOT USED |
| 7 |
|
| |||||||
|
|
| FAN |
|
| FP2 |
|
|
|
|
| ||||||
|
| G | G |
|
| 5 | 1 OR 3 |
| FP2 |
| FP2 |
| |||||
|
| 24VAC |
| LOW TEMP |
| TRIES |
| 8 |
| UNITS) OR VIO |
|
| |||||
|
| R | R |
|
| OFF | ON |
| RV 9 |
| BRN |
|
|
|
| ||
|
| COMMON |
|
|
|
| STATUS |
|
|
|
|
|
| ||||
|
| C |
|
|
| G |
|
|
|
|
| RVS |
| ||||
|
| ALARM | C |
|
|
|
| LED |
| 10 |
| ORG |
|
|
|
| |
|
| L | AL1 | JW1 |
|
|
|
|
| NOT USED |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |||||||
| SEE NOTE 6 FOR | AL2 |
|
| CXM |
|
| CO12 |
| YEL |
| CO |
| ||||
|
| SEE | MICROPROCESSOR |
| P2 |
|
|
|
|
|
| ||||||
|
| ALARM |
|
|
|
|
|
|
| ||||||||
| DRY ALARM CONTACT | A | NOTE 6 | CONTROL LOGIC |
|
|
|
|
|
|
|
| |||||
|
|
|
| P1 | RELAY |
|
|
|
|
| 24V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DC |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| EH1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| EH2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CO | P3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LEGEND |
AL | — Alarm Relay Contacts | PM |
|
|
|
|
|
| — Performance Monitor | ||
BR | — Blower Relay | PSC |
|
|
|
|
|
| — Permanent Split Capacitor | ||
CAP | — Compressor Capacitor | RVS |
|
|
|
|
|
| — Reversing Valve Solenoid | ||
CB | — Circuit Breaker | TRANS — Transformer Optional Wiring | |||||||||
CC | — Compressor Contactor |
|
|
|
|
|
|
|
|
| Field Line Voltage Wiring |
CO | — Sensor, Condensate Overflow |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Field Low Voltage Wiring | ||
COMP | — Compressor |
|
|
|
|
|
|
|
|
| |
FP1 | — Sensor, Water Coil Freeze Protection |
|
|
|
|
|
|
|
|
| Printed Circuit Trace |
FP2 | — Sensor, Air Coil Freeze Protection |
|
|
|
|
|
|
|
|
| Optional Wiring |
GND | — Ground |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||
HP | — |
|
|
|
|
|
|
|
|
| Relay/Contactor Coil |
JW | — Clippable Field Selection Jumper |
|
|
|
|
|
|
|
|
|
|
LOC | — Loss of Charge Pressure Switch |
|
|
|
|
|
|
|
|
| Thermistor |
P1 | — Field Wiring Terminal Block |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| ||||||
PB | — Power Block |
|
|
|
|
|
|
|
|
| Condensate Pan |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
Circuit Breaker
Relay Contacts — N.C.
Solenoid Coil
Relay Contacts — N.O.
Switch Temperature
Switch Low Pressure
Ground
Wire Nut
Splice Cap
*Optional wiring.
NOTES:
1.Compressor and blower motor thermally protected internally.
2.All wiring to the unit must comply with NEC and local codes.
3.Transformer is wired to 240 v (ORG) lead for 240/50/1 units, switch RED and ORG leads to PB(3) and insulate ORG lead.
4.FP1 thermistor provides freeze protection for water. When using antifreeze solutions, cut JW3 jumper.
5.Typical heat pump thermostat wiring shown. Refer to thermostat installation instructions for wiring to the unit.
6.
7.Transformer secondary ground via microprocessor board stand- offs and screws to control box. (Ground available from top two standoffs as shown.)
8.Fan motors factory wired for medium speed. For high or low speed remove BLU wire from fan motor speed tap “M” and con- nect to “H” for high or “L” for low.
Fig. 10 — Typical Aquazone™ Complete C Control Wiring
11