Adit 3500 - Release 1.6 27
Quick Start Guide
Basic Configuration
Basic Configuration
The following configuration is divided into logical sections, where each section configures an additional
function. The first must be configured before the second and so forth, however, you may stop at any
section and not add the following feature.
NOTE: The order in which commands are entered can affect the successful provisioning of
the Adit 3500.
zSetup Adit 3500 for access via Web-Browser
zRestore Factory Defaults
zModify Default Admin User
zConfigure WAN Interface for Internet Connectivity
zConfigure the Adit 3500 as a SIP Gateway

Setup Adit 3500 for access via Web-Browser

The following steps will configure the Adit 3500 to allow access to the Web Browser for configuration,
through the LAN (1) or WAN (2) 10/100Base-T Ethernet connections.
Note: for LAN access, no additional configuration is required to access the Adit using the web browser.
To configure the WAN access:
1. Connect to the CLI via the DB-9 RS-232. See Setting up a CLI Connection on page 24.
2. Enable the remote admin WAN access with the following command sequence:
Command Description
Username: admin
Password: ********
Log into the system (username and password).
Adit 3500> enable Enter the Privileged mode.
Password: ******** Enter password for the Privileged mode.
#configure terminal Enter the Configuration mode.
(config)# remote-admin web
primary-port enable
Enable remote web admin.