Registering department / flat-PLU keys by programming data

Basic Operations and Setups

Registering department / flat-PLU keys by programming data

REG

Mode switch

Preset price

Item

Unit price

($1.00)preset

 

Quantity

1

 

Dept.

2

Payment

Cash

$1.00

OPERATION

RECEIPT

 

 

 

 

 

 

 

 

 

"

 

 

 

 

 

1 DEPT02

•1.00

Department No. /

F

TL

•1.00

 

unit price

 

 

CASH

•1.00

 

 

 

 

 

 

 

 

 

Preset tax status

OPERATIONRECEIPT

Item 1

Unit price

($2.00)preset

 

Quantity

5

 

Dept.

3

 

Taxable

(1)preset

Item 2

Unit price

($2.00)preset

 

Quantity

1

 

Dept.

4

 

Taxable

(1)preset

Payment

Cash

$20.00

5

#

$

s 20-F

 

 

 

 

 

 

Tax status

5 DEPT03

 

 

•10.00

 

 

T1

 

 

 

1 DEPT04

T2

•2.00

 

 

 

TA1

 

 

•10.00

 

— Taxable Amount 1

TX1

 

 

•0.40

 

— Tax 1

TA2

 

 

•2.00

 

— Taxable Amount 2

TX2

 

 

•0.20

 

— Tax 2

TL

•12.60

 

 

 

CASH

 

 

•20.00

 

 

 

CG

 

 

•7.40

 

 

 

 

 

 

 

 

 

 

Locking out high amount limitation

OPERATIONRECEIPT

Item

Unit price

$1.05

 

Quantity

1

 

Dept.

3

 

Max.amount

($10.00)preset

Payment

Cash

$2.00

1050#

ERROR ALARM

(Exceeding high amount)

C

105# s 2-F

1 DEPT03

•1.05

TL

•1.05

CASH

•2.00

CG

•0.95

 

 

E