CDA HCG 931 manual Conversion to Natural Gas or LPG, Replacing the Burner Injectors, Cat: II 2H 3+

Models: HCG 931

1 20
Download 20 pages 23.93 Kb
Page 16
Image 16
Conversion to Natural Gas or LPG

16

Conversion to Natural Gas or LPG

Replacing the Burner Injectors

Remove the pan supports, the burner caps and flame speaders.

Using a wrench, substitute the nozzle injectors “J” (Figs. 19 - 20) with those most suitable for the kind of gas for which it is to be used.

The burners are conceived in such a way so as not to require the adjustment of the primary air.

Auxiliary,

 

Semi-Rapid

 

J

and Rapid

 

burners

 

Triple Ring burner

J

Fig. 19

Fig. 20

Table for the Choice of the Injectors

 

Cat: II 2H 3+

 

 

 

 

 

Burners

Nominal

Reduced

G30 - 28-30 mbar

G20 - 20 mbar

 

Power

Power

G31 - 37 mbar

 

 

kW

kW

Ø Injector

Ø Injector

 

 

 

 

 

 

1/100 mm

1/100 mm

 

 

 

 

 

Auxiliary (A)

1,00

0,30

50

72 (X)

 

 

 

 

 

Semi-Rapid (SR)

1,75

0,45

65

97 (Z)

Rapid (R)

3,00

0,75

85

115 (Y)

Triple Ring (TR)

3,50

1,50

95

135 (T)

 

 

 

 

 

Page 16
Image 16
CDA HCG 931 manual Conversion to Natural Gas or LPG, Replacing the Burner Injectors, Table for the Choice of the Injectors