16
Conversion to Natural Gas or LPG
Replacing the Burner Injectors
–Remove the pan supports, the burner caps and flame speaders.
–Using a wrench, substitute the nozzle injectors “J” (Figs. 19 - 20) with those most suitable for the kind of gas for which it is to be used.
The burners are conceived in such a way so as not to require the adjustment of the primary air.
Auxiliary, |
| |
| ||
J | ||
and Rapid | ||
| ||
burners |
|
Triple Ring burner
J
Fig. 19
Fig. 20
Table for the Choice of the Injectors |
| Cat: II 2H 3+ | ||
|
|
|
|
|
Burners | Nominal | Reduced | G30 - | G20 - 20 mbar |
| Power | Power | G31 - 37 mbar |
|
| kW | kW | Ø Injector | Ø Injector |
|
|
| ||
|
|
| 1/100 mm | 1/100 mm |
|
|
|
|
|
Auxiliary (A) | 1,00 | 0,30 | 50 | 72 (X) |
|
|
|
|
|
1,75 | 0,45 | 65 | 97 (Z) | |
Rapid (R) | 3,00 | 0,75 | 85 | 115 (Y) |
Triple Ring (TR) | 3,50 | 1,50 | 95 | 135 (T) |
|
|
|
|
|