VFS113 Rack/Desktop Model User’s Guide
2Select Scan Configuration and press Enter. The Scan Configuration screen displays.
3Select the number of seconds you want the router to wait and press Enter. You can select any number between 0 and 255.
The system confirms that you want to make the changes.
4Select Yes and press Enter to make the changes. The system confirms that the changes are made.
5Press Enter to return to the Configuration Menu.
Enabling and Disabling the Alarm
You can enable or disable the audible alarm that sounds when the router becomes too hot or detects low or high voltage. The alarm sounds a warning first. If the problem is not resolved, the alarm sounds a shutdown alarm. The router will then no longer transmit data until the problem is resolved.
The alarm conditions make the ST (status) light blink and also trigger an event message that displays in the Router Administrator software window and in the event log. See Displaying the Event Log on page