VFS113 Rack/Desktop Model User’s Guide

Table 4-1. POST diagnostic errors and solutions

Diagnostic FailureSolutions

Default hardware register

Replace the router.

 

 

Default chip set register

Replace the router.

 

 

Voltage/temperature

1. Check for thermal problems in the environment.

 

2. Check any airflow obstruction.

 

3. Replace the router.

 

 

Local DRAM memory test

Replace the router.

 

 

LVDS BIST

Replace the router.

 

 

PCI configuration

Replace the router.

verification

 

 

 

SCSI device scratch RAM

Replace the router.

 

 

I2C chip

Replace the router.

Buffer memory

Replace the router.

 

 

Programmable interval

Replace the router.

timer

 

 

 

Real-time clock chip

Replace the router.

 

 

Fibre Channel interface test

1. Check the firmware to make sure it matches the

 

hardware configuration. See Upgrading Firmware on

 

page 3-31if you need to update the firmware.

 

2. Replace the router.

 

 

Note: POST diagnostics only display a voltage/temperature warning or failure. It does not result in an error. Voltage/temperature failures cause router shutdown after the router has booted.

Problem: The system hangs after the “All diagnostic tests passed” message or while scanning devices.

Solution: Follow these steps to resolve the problem:

1Verify there are no SCSI address conflicts.

2Check the connected SCSI devices to make sure everything is properly connected and SCSI termination is correct. See Restoring the Default Configuration Through the Flash Utility.

3If the devices work properly, replace the router.

4-2