VFS113 Rack/Desktop Model User’s Guide
Table
Diagnostic Failure | Solutions |
Default hardware register | Replace the router. |
|
|
Default chip set register | Replace the router. |
|
|
Voltage/temperature | 1. Check for thermal problems in the environment. |
| 2. Check any airflow obstruction. |
| 3. Replace the router. |
|
|
Local DRAM memory test | Replace the router. |
|
|
LVDS BIST | Replace the router. |
|
|
PCI configuration | Replace the router. |
verification |
|
|
|
SCSI device scratch RAM | Replace the router. |
|
|
I2C chip | Replace the router. |
Buffer memory | Replace the router. |
|
|
Programmable interval | Replace the router. |
timer |
|
|
|
Replace the router. | |
|
|
Fibre Channel interface test | 1. Check the firmware to make sure it matches the |
| hardware configuration. See Upgrading Firmware on |
| |
| 2. Replace the router. |
|
|
Note: POST diagnostics only display a voltage/temperature warning or failure. It does not result in an error. Voltage/temperature failures cause router shutdown after the router has booted.
Problem: The system hangs after the “All diagnostic tests passed” message or while scanning devices.
Solution: Follow these steps to resolve the problem:
1Verify there are no SCSI address conflicts.
2Check the connected SCSI devices to make sure everything is properly connected and SCSI termination is correct. See Restoring the Default Configuration Through the Flash Utility.
3If the devices work properly, replace the router.