Chauvet 3P COLORcon setup, Single Row Application, Repeat Row Block Application, Controller Setup

Models: 3P

1 35
Download 35 pages 43.55 Kb
Page 16
Image 16
COLORcon™ setup

Operating Instructions

COLORcon™ setup

1.FIXTURE CONTROL PANEL SETUP

Activate ID addressing in each fixture by setting panel function {ID ON/OFF} to ON. {MENU} {Settings) {ID ON/OFF} [ON]

Set ID addresses in each fixture by setting panel function {ID address} to incremental values. (I.e. 1,2,3,4,5,6,etc…)

{MENU} {Settings} {ID address} [01 ~ 66] It is not necessary to set the DMX address.

2.CONTROLLER SETUP

When using the {Effect program} function, it is necessary to set the {Settings} {Range} setting, which is the quantity of fixtures in series.

{MENU} {Settings} {Range} [ (No. of fixtures) ]

Single Row Application

ID Address: 01

ID Address: 02

ID Address: 03

ID Address: 04

ID Address: 05

ID Address: 06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET

UP

DOWN EXIT

The figure above shows 6 fixtures connected in series with corresponding addresses. Each fixture has {ID ON} in the fixture’s settings. You must set the {Range} settings in the controller to [006] before accessing {Effect} programs.

Repeat Row Block Application

ID Address: 01

ID Address: 02

ID Address: 03

ID Address: 01

ID Address: 02

ID Address: 03

ID Address: 01

ID Address: 02

ID Address: 03

Block Application

ID Address: 01

ID Address: 02

ID Address: 03

ID Address: 04

ID Address: 05

ID Address: 06

ID Address: 07

ID Address: 08

ID Address: 09

The figure above shows 9 fixtures connected in series. Three rows comprised of 3 fixtures are addressed identically. Each fixture has {ID

ON} in the fixture’s settings. You must set the

{Range} settings in the controller to [003] before accessing {Effect} programs.

SET

UP

DOWN EXIT

The figure above shows 9 fixtures connected in series with corresponding addresses. Each fixture has {ID ON} in the fixture’s settings. You must set the {Range} settings in the controller to [009] before accessing {Effect} programs.

SET

UP

DOWN EXIT

COLORado™ 3P User Manual

16

3/17/2009 9:54 AM

Page 16
Image 16
Chauvet 3P user manual COLORcon setup, Single Row Application, Repeat Row Block Application, Fixture Control Panel Setup