CM2 | Installation Instructions |
CM2 Hardware Reference
Motor Control Hardware Information
(See figure 32)
RS485 Network Programmable Paramaters and Status Bit Assignments
RS485 Network Programmable Parameters
Parameter | Name | Range | Factory Default | Units |
Identifier |
|
|
|
|
|
|
|
|
|
0 | Custom Code | 0 | - | |
|
|
|
|
|
1 | Maximum Movement Time | 3100 | 0.01 sec | |
|
|
|
|
|
2 | Extend Speed | 100 | % | |
|
|
|
|
|
3 | Retract Speed | 100 | % | |
|
|
|
|
|
4 | Ramp UP Time | 100 | 0.01 sec | |
|
|
|
|
|
5 | Ramp DOWN Time | 100 | 0.01 sec | |
|
|
|
|
|
6 | Show Extend Delay | 100 | 1 sec | |
|
|
|
|
|
7 | Show Retract Delay | 100 | 1 sec | |
|
|
|
|
|
RS485 Network Status Bit Assignments
Bit | Name | Bit Location |
0 | At Home Position | - - - - - - - - - - - - - - - X |
|
|
|
1 | Move in Progress | - - - - - - - - - - - - - - X - |
|
|
|
2 | Network Operation in Progress | - - - - - - - - - - - - - X - - |
|
|
|
3 | Parameter Write Operations Enabled | - - - - - - - - - - - - X - - - |
|
|
|
4 | Network Command Error | - - - - - - - - - - - X - - - - |
|
|
|
8 | At Extend Limit | - - - - - - - X - - - - - - - - |
|
|
|
9 | At Retract Limit | - - - - - - X - - - - - - - - - |
|
|
|
22