Chief Manufacturing CM2 Determining Minimum I.D. of Furniture, Installation Instructions

Models: CM2

1 30
Download 30 pages 24.96 Kb
Page 9
Image 9
Determining Minimum I.D. of Furniture

Installation Instructions

CM2

NOTE: With the mount configured for the display and the

 

 

display installed, it is now possible to calculate the

Cover

 

minimum I.D of the cabinet.

Determining Minimum I.D. of Furniture

 

1.

Measure and record distance "A" in figure below.

 

 

(See figure 16)

 

2.

Measure and record distance "B" from figure below. This is

 

 

the material thickness of the cover that will be mounted to

 

 

the CM2. (See figure 16)

 

3.

Add measurements from step one and two together. The

 

 

total is the minimum inside height of the furniture.

 

4.

Measure and record distance "C" in figure below. This

 

 

dimension is from the back side of the CM2 vertical

 

 

mounting bracket to the furthest point forward on the

 

 

display. (See figure 16)

 

 

CAUTION: IMPROPER FIT TOLERANCES CAN CAUSE

Base

 

AREAS OF MOUNT OR FURNITURE TO COLLIDE WHEN

 

 

OPERATING THE MOUNT CAUSING SERIOUS DAMAGE

 

TO EQUIPMENT! Always provide for adequate tolerances

Figure 15

when building cabinet esopecially between base and cover.

(See figure 15)

WARNING: EXCEEDING STATED WEIGHT LIMITS OF

THE CM2 CAN LEAD TO SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT! The weight of furniture cover must be calculated into the total weight being placed on the mount a total not exceed 180lbs (82 kg) the maximum capacity of the CM2.

 

C

B

C

 

A

Figure 16