Send document comments to nexus7k-docfeedback@cisco.com

6-7

Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-18634-01
Chapter 6 Managing the Device Hardware
Displaying Power Usage Information
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00
License software-module specific block:
Block Signature : 0x6006
Block Version : 1
Block Length : 16
Block Checksum : 0x77
lic usage bits:
00 00 00 00 00 00 00 00
Second Serial number specific block:
Block Signature : 0x6007
Block Version : 1
Block Length : 28
Block Checksum : 0x312
Serial Number : TBM11476798
switch#
Displaying Power Usage Information

To display the actual power usage information for the entire device, use the show environment power

command. See Example 6-4.

Note In a Cisco Nexus 7000 Series device, power usage is reserved for both su pervisor modules regardless of

whether one or both supervisor modules are present.

Example 6-4 Displaying Power Management Information

switch# show environment power
Power Supply:
Voltage: 50 Volts
-----------------------------------------------------
PS Model Power Power Status
(Watts) (Amp)
-----------------------------------------------------
1 N7K-AC-6.0KW 3000.00 60.00 Ok
2 N7K-AC-6.0KW 3000.00 60.00 Ok
3 N7K-AC-6.0KW 0.00 0.00 Shutdown
Mod Model Power Power Power Power Status
Requested Requested Allocated Allocated
(Watts) (Amp) (Watts) (Amp)
--- ------------------- ------- ---------- --------- ---------- ----------
1 N7K-M132XP-12 773.50 15.47 773.50 15.47 Powered-Up