Chapter 8 Removal and Installation Procedures

Replacing a CompactFlash Card

Se n d d o c u m e n t c o m m e n t s t o n ex u s 7 k - d o c f e e d b a ck @ c i s c o . c o m

If the card does not fit easily into the slot, flip the card so the bottom edge is on top, and try pushing the card into the slot.

Step 7 Wait for the reader LED to turn green and for a message to appear on the console.

If you are installing a card into the log flash reader, the message will end with “logflash:online.”

switch# 2008 Mar 15 08:00:00 switch %$ VDC-1 %$ %IDEHSD-2-MOUNT: logflash:online

If you are installing a card into the expansion flash reader, the message will end with “slot0:online.”

switch# 2008 Mar 15 08:00:00 switch %$ VDC-1 %$ %IDEHSD-2-MOUNT: slot0:online

If you see an offline message or do not see a message, either the card is not fully pushed into the reader or it is improperly formatted.

switch# 2008 Dec 1 12:00:00 switch %$ VDC-1 %$ %IDEHSD-2-UMOUNT:logflash:offline

Make sure that the card is fully inserted inside the reader. If the card is fully inserted, either format the card (see the Cisco NX-OS Fundamentals Configuration Guide, Release 4.0) or replace the card with another card that is properly formatted for the reader.

Step 8 Remove the bottom frame assembly by completely unscrewing the four screws identified in Figure 8-5.

Figure 8-5 Removing the Bottom Frame

186696

Step 9 Remove the front doors on the middle of the frame by unscrewing the six screws (three on each side) identified in Figure 8-6.

 