74
Location
The Management Interface modules are located at the top of back the chassis. Refer to Figure 5-5 to
view the chassis diagram.
Figure 5-6: Management Interface Module LEDs
Interpreting the Management Interface LEDs
System Status LEDs
Management Interface Status LEDs
Table 5-7: Interpreting the Management Interface Module System Status LEDs (see Figure
5-6)
Color State Indication
Green and Yellow off No module power, or LED failure.
Green solid on System running with no errors detected.
Green off No power to the Management Interface module, LED failure,
or yellow LED is ON.
Yellow solid on At least one module failure in the system. Operator attention
required.
The “!” label indicates a failure.
Yellow blinking Identify. Assists in identifying a particular Field Replaceable
Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the diag LED test.
Refer to the Command Line Reference Guide for more
information.
Example:
Run the identity test on Power Supply 1:
config mode -> diag card 15 ->
test led ->
-> start - start flashing
-> stop - stop flashing
Table 5-8: Interpreting the Management Interface Module Status LEDs (see Figure 5-6)
Color State Indication
Green over Yellow off No module power, or LED failure.
Green solid on The Management Interface module is running with no errors
detected.