4.Use the show diag fru-errorcommand to display any errors that appear in the result-string.

Example

SFS-270#show diag fru-error

============================================================

Fru-Error

============================================================

fru-slot fru-error

------------------------------------------------------------

card(1)

none

card(2)

none

card(7)

none

card(8)

none

card(9)

none

card(10)

none

card(11)

none

card(12)

none

card(13)

none

card(14)

none

card(15)

none

card(17)

none

fan(1)

none

fan(2)

none

 

5. Reboot the chassis when the self-test is complete.

Example

SFS-270# reload

System configuration is modified. Save? [yes(default) no filename] y Proceed with reload? [yes(default) no] y

Run Power Supply Tests

The following tests are available to locate and diagnose fan modules:

LED page 98

Self-Test page 99

Run a LED Test on the Power Supply

Use the LED test to blink the LED and identify a specific power supply.

Example

SFS-270> enable

 

SFS-270# config

 

SFS-270(config)#diag power-supply 1

test led

SFS-270(config-diag-power-supply-1)#

SFS-270(config-diag-power-supply-1)#

start

SFS-270(config-diag-power-supply-1)#

stop

SFS-270(config-diag-power-supply-1)#

 