Cisco Systems MDS 9200 Series manual Module Specifications

Models: MDS 9200 Series

1 164
Download 164 pages 61.43 Kb
Page 122
Image 122
Module Specifications

Appendix B Technical Specifications

Module Specifications

Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m

Table B-2lists the physical specifications for the Cisco MDS 9200 Series.

Table B-2

Physical Specifications for the Cisco MDS 9200 Series

 

 

Description

Specification

 

 

Dimensions

5.25 x 17.5 x 22.75 in. (13.3 x 44.5 x 57.8 cm)

(HxWxD)

Chassis requires 3 RU1.

 

Chassis depth including cable guide is 27.75 in. (70.3 cm).

 

 

Weight

Chassis only: 31 lb (14.1 kg).

 

Chassis configured with one supervisor module, fan module, and

 

two power supplies: 53.3 lb (24.3 kg).

 

 

Power supply

845-W AC input for each power supply

 

 

Airflow

300 lfm2 through system fan module, or 80 cfm3 per supervisor,

 

switching, or services module. Total of 160 cfm if slot 2 is filled.

 

Spacing requirements:

If installed in a cabinet, a minimum of 2.5 in. (6.4 cm) is required between the chassis air vents and the cabinet walls.

If installed in an open rack (no side panels), the horizontal distance required between the chassis and any devices that exhaust air towards the chassis is a minimum of 6 in.

(15.2 cm), and the distance required between the chassis air vents and any walls is a minimum of 2.5 in. (6.4 cm).

1.RU = rack unit; 1 RU = 1.75 inches (4.45 cm)

2.lfm = linear feet per minute

3.cfm = cubic feet per minute

Table B-3lists the specifications for the Cisco MDS 9200 Series supervisor module (which is fixed in the chassis) and the switching and services modules.

Module Specifications

This section provides the Cisco MDS 9200 Series module specifications.

Table B-3 Cisco MDS 9200 Series Module Specifications

Description

Specification

Environmental Requirements

 

 

 

 

Temperature, certified for operation

32 to 104°F (0 to 40°C)

 

 

 

 

 

 

 

 

 

 

 

 

Temperature, designed and tested

32 to 130°F (0 to 55°C)

 

 

 

 

for operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature, ambient nonoperating

-40 to 167°F (-40 to 75°C)

 

 

 

 

and storage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Humidity (RH), ambient

10 to 90%

 

 

 

 

(noncondensing) operating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Altitude, certified for operation

0 to 6500 ft (0 to 2000 m)

 

 

 

 

 

 

 

 

 

 

 

Cisco MDS 9200 Series Hardware Installation Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B-2

 

 

 

 

OL-17468-02

 

 

 

 

 

 

Page 122