LEDs on the Fibre Channel Advanced Services Module

Chapter 1 Product Overview

Services Modules

Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m

LEDs on the Fibre Channel Advanced Services Module

Table 1-10describes the LEDs for the Cisco MDS 9000 Family ASM.

Table 1-10

LEDs for the Cisco MDS 9000 Family ASM

 

 

 

 

LED

 

Status

Description

 

 

 

 

Status

 

Green

All diagnostics pass and the module is operational (normal

 

 

 

initialization sequence).

 

 

 

 

 

 

Orange

One of the following occurs or occurred:

 

 

 

The module is booting or running diagnostics (normal

 

 

 

initialization sequence).

 

 

 

The inlet air temperature of the system exceeded the

 

 

 

maximum system operating temperature limit (a minor

 

 

 

environmental warning). To ensure maximum product life,

 

 

 

you should immediately correct the environmental

 

 

 

temperature and restore the system to normal operation.

 

 

 

 

 

 

Red

One of the following occurs or occurred:

 

 

 

The diagnostic test failed. The module is not operational

 

 

 

because a fault occurred during the initialization sequence.

 

 

 

The inlet air temperature of the system exceeded the safe

 

 

 

operating temperature limits of the card (a major

 

 

 

environmental warning). The card shut down to prevent

 

 

 

permanent damage.

 

 

 

 

Speed

 

On

2-Gbps mode.

 

 

 

 

 

 

Off

1-Gbps mode.

 

 

 

 

Link

 

Solid green

Link is up.

 

 

 

 

 

 

Steady flashing

Link is up (beacon used to identify port).

 

 

green

 

 

 

 

 

 

 

Intermittent

Link is up (traffic on port).

 

 

flashing green

 

 

 

 

 

 

 

Solid yellow

Link is disabled by software.

 

 

 

 

 

 

Flashing yellow

A fault condition exists.

 

 

 

 

 

 

Off

No link.

 

 

 

 

Caching Services Module

The Caching Services Module (CSM) provides virtualization services that allow the Cisco MDS 9000 Family switches to reallocate physical resources as virtual resources for increased efficiency. The CSM receives and sends data through the switch backplane. It has two disk drives, two internal batteries for backup in case of power failure, and no external ports.

CSMs must be implemented in pairs in the fabric to provide redundancy and backup. Only two or more CSMs in a fabric are supported. However, the CSMs need not to be installed in the same switch.

 

 

Cisco MDS 9200 Series Hardware Installation Guide

 

 

 

 

 

 

OL-17468-02

 

 

1-31

 

 

 

 

 

Page 49
Image 49
Cisco Systems MDS 9200 Series manual Caching Services Module, LEDs on the Fibre Channel Advanced Services Module, 1-31