Cisco Systems MDS 9200 Series manual Power Supplies, 1-35

Models: MDS 9200 Series

1 164
Download 164 pages 61.43 Kb
Page 53
Image 53
Power Supplies

Chapter 1 Product Overview

Power Supplies

Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m

Power Supplies

The Cisco MDS 9200 Series supports dual hot-swappable 845-W AC power supplies, each of which can supply sufficient power to the entire chassis should one power supply fail. The power supplies monitor their output voltage and provide status to the supervisor module. To prevent the unexpected shutdown of an optional module, power management software only allows a module to power up if adequate power is available.

The Cisco MDS 9200 Series power supplies can be configured to be redundant or combined. By default, they are configured as redundant, so that if one fails, the remaining power supply can still power the entire system. For information on how to configure the power supplies, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide.

The power supplies, which are accessed from the rear of the chassis, are illustrated in Figure 1-24.

Figure 1-24 Cisco MDS 9200 Series with 845-W Dual Power Supplies

 

4

 

 

 

PWR-845-AC

PWR-845-AC

 

1

INPUT OK

 

INPUT OK

FAN OK

 

FAN OK

OUTPUT FAIL

 

OUTPUT FAIL

2

100-240V 12-5A

100-240V 12-5A

 

 

 

 

50/60 Hz

50/60 Hz

 

 

ALL FASTENERS MUST BE FULLY ENGAGED

ALL FASTENERS MUST BE FULLY ENGAGED

94002

 

PRIOR TO OPERATING OF POWER SUPPLY

PRIOR TO OPERATING OF POWER SUPPLY

 

 

 

 

3

 

 

1

Power supply switch

3

Power supply handle

 

 

 

 

2

AC power connection

4

Power supply LEDs

 

 

 

 

Table 1-12describes the LEDs for the Cisco MDS 9200 Series power supplies.

Table 1-12

LEDs for the Cisco MDS 9200 Series Power Supplies

 

 

 

 

LED

 

Status

Description

 

 

 

 

Input OK

 

Green

AC input is good and power supply is functioning normally.

 

 

 

 

 

 

Off

Power supply is turned off or is not seated properly in the

 

 

 

chassis.

 

 

 

 

Fan OK

 

Green

Power supply fans are operating properly.

 

 

 

 

 

 

Off

Fan is not operating or power supply is off.

 

 

 

 

Output Fail

 

Red

Power supply is not in a stable state. If this indication

 

 

 

continues after initial power on, check that all connections

 

 

 

are secure, including the system fan tray.

 

 

 

 

 

 

Off

Normal operation or power supply is turned off.

 

 

 

 

Cisco MDS 9200 Series Hardware Installation Guide

 

OL-17468-02

1-35

 

 

 

Page 53
Image 53
Cisco Systems manual 1-35, 24 Cisco MDS 9200 Series with 845-W Dual Power Supplies