2-28
Cisco SFS 7024 Hardware Users Guide
OL-8794-02
Chapter
AC OK
Amber indicates that AC power is normal.
Off indicates a AC power failure or no AC power is present.
SFS 7024 Leaf and Spine Module LEDs

Leaf Module IB Port LEDs

Each SFS 7024 leaf module port has a Blue IB link status LED that provide the following indications:
On - the logical link is up (port is in the Active state).
Slow Blink - the physical link is up (port is in the Initialization state).
Fast Blink - IB data is flowing through the port.
Off - the physical link is down (port is in the Down state).

Spine and Leaf Module Status LED

The status LED indicates one of the following conditi ons:
Steady Green - the module is operating normally.
Blinking Green (twice per second) - transitioning to the removal state.
Blinking Green (once every four seconds) - LED test state.
Off - module is in the removable state.

Spine and Leaf Module Attention LED

The Attention LED indicates one of the following conditions:
Off - the system functioning normally.
Steady Amber - the system requires some attention, which could indicate one of the following
conditions:
The switch temperature is at a warning level on the module.
The switch silicon temperature is at a warning level (approximately 90 degrees C).
DC voltages on the board are slightly out of tolerance (12V Bulk, 5 V, 3.3V, 1.8V, VBIO are all
monitored).
The module can no longer function properly. The system will take the appr opriate actions to
ensure that no damage is done to its components.
Blinking Amber (once every four seconds) - LED test state.

Spine Module Management LEDs

Each SFS 7024 spine module has three management LEDs:
Capable:
Green indicates that the spine slot supports management.
Off indicates that the spine slot does not support management.
Stat: