2-22
Cisco SFS 7024 Hardware Users Guide
OL-8794-02
Chapter
Note If the spine module RS-232 port is connected to a terminal emulation program, the user will be able to
view the switch boot process. Be certain to use a null-modem/crossover serial cable for the console port.
The settings for the terminal emulation device should be:
8 data bits
no parity bits
1 stop bit
56K baud
Use VT100 emulation.
Flow control = XON/XOFF
Figure 2-9 SFS 7024 RS-232 Connector
Step 3 Verify the IP address with the command line interface (CLI) command showChassisIpAddr
command. The system returns the information similar to the following:
Chassis IP Address: 192.168.100.9 Net mask: 0xffffff00
Changing the SFS 7024 IP Address and Default Gateway via the CLI
Note The following tasks must be performed for both the upper and lower hemispheres of the SFS 7024.
The CLI can be accessed via Telnet, SSH, or through the SFS 7024 RS232 serial ports.
Step 1 Connect null-modem/crossover serial cables to the RS-232 ports of the SFS 7024. If using a terminal
emulation device, the settings should be:
8 data bits
no parity bits
1 stop bit
Spine 1 (Managed)
Fan
3
Fan
1
S
PS
5
PS
4
PS
3
PS
2
PS
1
Spine 2 (Managed)
Spine 3 (Unmanaged)