2-32
Cisco SFS 7024 Hardware Users Guide
OL-8794-02
Chapter
Step 1 Remove the module by pushing up on the handles to disengage from the lock notch. Once the handles
are disengaged, gently pull the handles out and slide the module out of the slot.
Step 2 To install a module, hold it so that the ejector handles are on the bottom.
Step 3 Pull the handles out to extend them. Slide the module into the appropriate slot of the chassis until it
makes contact with the backplane. As the module seats in the chassis, the handles will begin to close.
Step 4 Push the handles in to fully close.
Hot Swapping the Fan Unit
Step 1 Loosen the captive panel screw.
Step 2 Pull the panel screw down to partially disengage the unit.
Step 3 Slowly pull the unit. The unit will disengage from the connector.
Step 4 Carefully slide the fan out until it is completely removed from its slot.
To install a fan unit:
Step 1 Place the unit into the slot. Slowly slide the fan unit in until it engages into the connector.
Step 2 Using the panel screw, push up to re-engage the unit.
Step 3 Tighten the captive panel screw.
Hot Swapping Power Supplies
The SFS 7024 switch requires a minimum of four power supplies for normal operation. Power supplies
can be hot swapped without powering down the switch. To replace a power supply:
Step 1 Loosen the captive panel screw.
Step 2 Pull the panel screw down to partially disengage the unit.
Step 3 Slowly pull the unit. The unit will disengage from the connector.
Step 4 Carefully slide the power supply out until it is completely removed from its slot.
Step 5 To install a power supply:
Step 6 Place the unit into the slot. Slowly slide the power supply in until it engages into the connector.
Step 7 Using the panel screw, push up to re-engage the unit.
Step 8 Tighten the captive panel screw.