2-26
Cisco SFS 7024 Hardware Users Guide
OL-8794-02
Chapter
startup script (s) :
other (o) : sbe
Loading package from flash device /image1 ...
Boot System = 7024
Boot Image Information:
Product = SFS7012
BSP = t3
Version = 3.3.0.0.4
Compressed Image Size = 3616523 bytes
md5 = 46086777be1b5bae45140a440425b915
vxWorks Image Type = loadable
Computed md5 = 46086777be1b5bae45140a440425b915
md5 values match!
11088736
Starting at 0x80010000...
sysI
REGS
BOOT
Initializing HyperTransport bus
HyperTransport initialization completed
Found Intel Strata Flash 128 MBit (0x8918).
Mounted raw file system on device /image1. (size=6291456 bytes)
Mounted raw file system on device /image2. (size=6291456 bytes)
Mounted raw file system on device /dump0. (size=1048576 bytes)
Mounted flash file system on device /rfa1. (size=2097152 bytes)
Network configuration requested.
cliEnabled=1
sbe0 speed=100 fullDuplex=0 flowControl=0
sbe1 speed=100 fullDuplex=1 flowControl=0
Note The command spineip changes the IP address for image1 and image2,

Verifying Start-up

The following are ways to determine that the system has started successfully:
The IB link status indicator LEDs are lit up on the switch ports which are c onnected to an IB host.
The user is able to bring up the Chassis Viewer (for each hemisphere) through a web browser on the
OOB LAN. The home page displays the front and back views of the SFS 7024 switch.
SFS 7024 Component LEDs

Chassis Status LED

The chassis status LED is Green when the system is functioning normally.
The chassis status LED is Amber when one of the following conditions exists:
The system ambient temperature exceeds 52 C but remains less than 60 C.
Any Fan Alarm is amber.
Any power supply AC OK LED is off.
Any power supply DC OK LED is off