Status and Statistics
View Log
Cisco Small Business 200, 300 and 500 Series Managed Switch Administration Guide (Internal Version) 27
2
Rising Event—Select an event to be performed when a rising event is
triggered. Events are created in the Events page.
Falling Threshold—Enter the value that triggers the falling threshold alarm.
Falling Event—Select an event to be performed when a falling event is
triggered.
Startup Alarm—Select the first event from which to start generation of
alarms. Rising is defined by crossing the threshold from a low-value
threshold to a higher-value threshold.
-Rising Alarm—A rising value triggers the rising threshold alarm.
-Falling Alarm—A falling value triggers the falling threshold alarm.
-Rising and Falling—Both rising and falling values trigger the alarm.
Interval—Enter the alarm interval time in seconds.
Owner—Enter the name of the user or network management system that
receives the alarm.
STEP 4 Click Apply. The RMON alarm is saved to the Running Configuration file.
View Log
See Viewing Memory Logs.