CBM-270 User’s Manual

5.3Jumper Wire Function

The jumper wires have been set at shipment. The following lists the basic settings at shipment. Check the settings by performing self-printing.

Jumper Wires

No.

Function

Short

Open

Upon

Shipment

 

 

 

 

J1

 

 

 

Short

J2

International character

See Table 3

Short

J3

 

 

 

Short

J4

Data bit length

7 bits

8 bits

Open

J5

Unused

-

-

Open

J6

Label detection

Black mark

Label interval

Open

J7

Unused

-

-

Open

J8

Communication error mark

Ignored

"?" printed

Open

*J4: Serial interface only. Disabled for the parallel one.

*J5~J7: Do not change the shipment settings.

Table 3

No.

USA

France

Germany

U.K.

Denmark-I

Sweden

Italy

Japan

J1

Short

Open

Short

Open

Short

Open

Short

Open

J2

Short

Short

Open

Open

Short

Short

Open

Open

J3

Short

Short

Short

Short

Open

Open

Open

Open

CAUTION:

1)Never change the settings of the jumper wires.

2)If you want to change their settings, consult us.

3)Never disassemble the printer body. It could cause trouble, etc.

33

CITIZEN

Page 33
Image 33
Citizen CBM-270 user manual Jumper Wire Function, Usa