6.3Input and Output Signals
6.3.1Input and Output Signals
(1) Input signals to the printer
·DATA | : | |||
· |
|
|
| : Strobe signal to read the |
STROBE | ||||
|
|
|
| |
·RESET | : Signal to reset the entire printer (Negative logic); 1 ms or more |
(2) Output signals from the printer
·ACK :
: Signal to indicate that the printer is busy. Input new data when it is "Low." (Positive logic)
: Turned to "Low" when the printer has an alarm. At this time, all the control circuits in the printer stop. (Negative logic)
: Output if the printing paper has run out or is running out. (Positive logic)
(3) Power source and the related
·+5 V DC | : 5 V output pulled up by a 10kW resistor |
·GND | : Common ground for the circuits |
35 | CITIZEN |