5.DIP SWITCH SETTING

5.1Location of DIP Switch

1.Turn off the power.

2.Detach the printer cover, and take out the paper roll. (The switch is found under the paper roll.)

3.There are 2 switches (8-pole and 4-pole) for the serial interface, and 1 switch (8-pole) for the parallel interface.

5.2DIP Switch Function

DS1

No.

Function

ON

OFF

Upon Shipment

1

PNE selection

Enabled

Disabled

ON

2

CR switching

LF operation

Ignored

OFF

3

Print density

See Table 1

ON

4

OFF

 

 

 

5

Paper selection

Label paper

Thermal paper

OFF

6

Auto-loading

Enabled

Disabled

ON

7

DTR/DSR, XON/XOFF

XON/XOFF

DTR/DSR

OFF

8

Kanji code selection

S-JIS

JIS

OFF

*DS1-7: Enabled only for the serial interface. Disabled for the parallel one.

DS2 (For Serial Interface Only)

No.

 

Function

 

 

ON

 

OFF

Upon Shipment

 

1

 

 

 

 

 

 

 

 

 

OFF

 

2

Baud rate and parity

 

See Table 2

OFF

 

3

setting

 

 

OFF

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

OFF

 

Table 1

 

 

 

 

 

 

 

 

 

 

 

 

Light

Standard

Slitly Dark

 

Dark

 

 

 

 

 

 

 

 

 

 

DS1-3

OFF

ON

OFF

 

ON

 

 

 

 

DS1-4

OFF

OFF

ON

 

ON

 

 

Table 2

 

 

 

 

 

 

 

 

 

 

 

DS2-4

DS2-3

DS2-2

DS2-1

 

Parity

 

Baud Rate

 

 

 

 

 

 

OFF

OFF

OFF

OFF

 

None

 

9,600 bps

 

 

OFF

OFF

OFF

ON

 

None

 

1,200

 

 

OFF

OFF

ON

OFF

 

None

 

2,400

 

 

OFF

OFF

ON

ON

 

None

 

4,800

 

 

OFF

ON

OFF

OFF

 

None

 

9,600

 

 

OFF

ON

OFF

ON

 

None

 

19,200

 

 

OFF

ON

ON

OFF

 

Odd

 

1,200

 

 

OFF

ON

ON

ON

 

Odd

 

2,400

 

 

ON

OFF

OFF

OFF

 

Odd

 

4,800

 

 

ON

OFF

OFF

ON

 

Odd

 

9,600

 

 

ON

OFF

ON

OFF

 

Odd

 

19,200

 

 

ON

OFF

ON

ON

 

Even

 

1,200

 

 

ON

ON

OFF

OFF

 

Even

 

2,400

 

 

ON

ON

OFF

ON

 

Even

 

4,800

 

 

ON

ON

ON

OFF

 

 

Even

 

9,600

 

 

ON

ON

ON

ON

 

 

Even

 

19,200