SECONDARY CO2 REGULATORS

SECONDARY CO2 REGULATORS

The secondary CO2 regulators, located inside the Unit, control CO2 pressure to the Unit carbonator(s) and the product blender tanks. If adjustment of these CO2 regulators should become necessary, call a qualified Service Person to make the adjustments.

ADJUSTING BRIX (WATER-TO-SYRUP “RATIO”) OF DISPENSED PRODUCT

BRIX is the Water-to-Syrup “Ratio” of the dispensed product and should be periodically checked and if neces- sary, be adjusted by a qualified Service Person.

REPLENISHING SYRUP SUPPLY

SYRUP TANKS SYSTEM

NOTE: Sugar-free diet syrup cannot be used with this Unit.

Although syrup replenishing can be done anytime, the syrup supply must be replenished when either the ‘‘SYRUP 1’’ or ‘‘SYRUP 2’’ fault messages are displayed on the message display indicating either No. 1 or No. 2 syrup system syrup tank is empty.

NOTE: The following instructions are applicable only when replenishing the syrup supply. Refer to SYRUP FLAVOR CHANGE when changing syrup flavors.

1.Press applicable ‘‘OFF’’ switch on the control panel to stop the applicable freeze cylinder beater and refrig- eration system.

IMPORTANT: The following CO2 and liquid disconnect and connecting procedure for the syrup tank replacement or filling the syrup tank in place must be performed in the order as follows:

To disconnect syrup tank from the Unit syrup system.

First, disconnect liquid disconnect from the syrup tank. NOTE - Disconnecting the liquid quick dis- connect from the syrup tank first prevents syrup from backflowing through the Unit syrup flow regulator which may alter the regulator adjustment.

Second, disconnect CO2 quick disconnect from the syrup tank.

To connect syrup tank into the Unit syrup system.

First, connect CO2 quick disconnect to the syrup tank to pressurize the tank.

Second, connect liquid quick disconnect to the syrup tank.

2.Disconnect inlet (CO2) and outlet (syrup) lines from the empty syrup tank.

3.Check syrup tank quick disconnects for sticky or restricted operation. Rinse the disconnects in warm water.

4.First, pressurize the full syrup tank by connecting CO2 line to the tank, then connect the Unit syrup inlet line to the tank.

5.Press applicable ‘‘SYRUP PRIME’’ switch to fill applicable No. 1 or No. 2 syrup system syrup float switch with syrup.

6.Press applicable “BLEND ON/OFF’’ switch to fill applicable No. 1 or No. 2 system product blender tank with product.

7.Press applicable ‘‘ON’’ switch to start the refrigeration system and beater in applicable No. 1 or No. 2 freeze cylinder.