Cornelius R-404A manual Troubleshooting Product Blender Tanks And Carbonators

Models: R-404A

1 28
Download 28 pages 1.64 Kb
Page 23
Image 23
TROUBLESHOOTING PRODUCT BLENDER TANKS AND CARBONATORS

Trouble

 

Probable Cause

 

Remedy

‘‘CO2 OUT’’ FAULT MESSAGE

A.

CO2 supply turned off or

A.

Open CO2 cylinder shutoff valve

GOES ON DURING

 

exhausted.

 

or replenish CO2 supply as

OPERATION.

 

 

 

instructed.

 

B.

Primary CO2 regulator set too

B.

Call qualified Service Person to

 

 

low.

 

adjust primary CO2 regulator.

 

C.

Inoperable CO2 pressure

C.

Call qualified Service Person.

 

 

switch.

 

 

 

 

 

 

 

‘‘H2O OUT’’ FAULT MESSAGE

A.

Water supply turned off or

A.

Turn on water supply or check

GOES ON DURING

 

water pressure inadequate.

 

water supply line pressure.

OPERATION.

 

 

 

 

 

B.

Plugged water filter.

B. Change water filter cartridge.

 

C.

Inoperative water pressure

C.

Call qualified Service Person.

 

 

switch.

 

 

 

 

 

 

 

‘‘SYRUP 1’’ OR ‘‘SYRUP 2’’

A.

Syrup supply exhausted.

A.

Replenish syrup supply as

FAULT MESSAGE GOES ON

 

 

 

instructed.

DURING OPERATION.

 

 

 

 

 

 

 

 

 

‘‘ERROR 1’’ OR ‘‘ERROR 2’’

A.

Error within Unit has

A.

Press ‘‘ERROR RESET’’ switch to

FAULT MESSAGE GOES ON

 

developed interrupting normal

 

restore normal operation or call

DURING OPERATION.

 

operation.

 

qualified Service Person.

 

 

 

 

 

FREEZE CYLINDER

A.

Inoperable automatic defrost

A.

Call qualified Service Person.

AUTOMATIC DEFROST

 

timer.

 

 

CYCLE DOES NOT

 

 

 

 

OPERATE.

 

 

 

 

 

 

 

 

 

UNIT DOES NOT GO OFF

A.

Automatic defrost timer stuck

A.

Call qualified Service Person.

AUTOMATIC DEFROST

 

in automatic defrost cycle.

 

 

CYCLE.

 

 

 

 

 

 

 

 

 

MANUAL DEFROST CYCLE

A. Master circuit board not

DOES NOT OPERATE WHEN

operating properly.

‘‘DEFROST’’ SWITCH IS

 

PRESSED.

 

A.Call qualified Service Person.

DEFROST CYCLE DOES NOT

A.

Master circuit board not

A.

Call qualified Service Person.

CANCEL AFTER PRESSING

 

operating properly.

 

 

‘‘CANCEL DEFROST ’’

 

 

 

 

SWITCH.

 

 

 

 

 

TROUBLESHOOTING PRODUCT BLENDER TANKS AND CARBONATORS

 

 

 

 

CARBONATOR WATER PUMP

A.

No electrical power to Unit.

A. Connect electrical power to Unit.

MOTOR WILL NOT OPERATE.

 

 

 

Check power source.

 

B.

‘‘BLEND ON/OFF’’ switch has

B.

Press ‘‘BLEND ON/OFF’’ switch.

 

 

not been pressed.

 

 

C.‘‘H2O OUT’’ fault message is on.

C.Restore water supply to Unit.

D.‘‘CO2 OUT’’ fault message is on.

D.Replenish CO2 supply as instructed.

E. Inoperative water pump and/or E. Call qualified Service Person. motor.

312030002

18

Page 23
Image 23
Cornelius R-404A manual Troubleshooting Product Blender Tanks And Carbonators