BAG–IN–BOX SYSTEM

8.If freeze cylinder is not full of product, repeatedly pull and release the faceplate relief valve to slowly bleed

CO2 from the freeze cylinder and allow product to fill the cylinder. Do not relieve freeze cylinder pressure too fast or the product will foam excessively in the cylinder and lose carbonation.

BAG–IN–BOX SYSTEM

1.Press applicable ‘‘OFF’’ switch on the control panel to stop the applicable freeze cylinder beater and refrig- eration system.

2.Disconnect syrup outlet tube from empty bag-in-box container, then remove empty container.

3.Open flap on full bag-in-box container.

4.Pull bag-in-box container connector from the container, then remove dust cap from the connector.

5.Rinse syrup outlet tube in warm water.

6.Connect syrup outlet tube to full bag-in-box container. Make sure syrup outlet tube is securely connected to the container.

7.Press applicable ‘‘SYRUP PRIME’’ switch to fill applicable No. 1 or No. 2 syrup system syrup float switch with syrup.

8.Press applicable “BLEND ON/OFF’’ switch to fill applicable No. 1 or No. 2 system product blender tank with product.

9.Press applicable ‘‘ON’’ switch to start the refrigeration system and beater in applicable No. 1 or No. 2 freeze cylinder.

10.If freeze cylinder is not full of product, repeatedly pull and release the faceplate relief valve to slowly bleed

CO2 from the freeze cylinder and allow product to fill the cylinder. Do not relieve freeze cylinder pressure too fast or the product will foam excessively in the cylinder and lose carbonation.

SYRUP FLAVOR CHANGE

The Unit syrup system that the syrup flavor change will be made on must be sanitized before connecting new flavor syrup to the system. It may be necessary to readjust BRIX (Water-To-Syrup) “Ratio” of the dispensed product after making a syrup flavor change.

REPLENISHING CO2 SUPPLY

The Unit and it’s syrup supply source may be connected to either a bulk CO2 supply or to a CO2 cylinder. If your Unit is connected to a CO2 cylinder, proceed as follows to replenish the CO2 supply.

WARNING: CO2 displaces oxygen. Strict attention must be observed in the prevention of CO2 (carbon dioxide) gas leaks in the entire CO2 and soft drink system. If a CO2 gas leak is suspected, particularly in a small area, immediately ventilate the contaminated area before

attempting to repair the leak. Personnel exposed to high concentration of CO2 gas will experience tremors which are followed rapidly by loss of consciousness and suffocation.

NOTE: When indicator on primary CO2 cylinder regulator assembly 1800-psi gage is in shaded (‘‘change CO2 cylinder’’) portion of the dial, CO2 cylinder is almost empty and should be changed.

1.Fully close (clockwise) CO2 cylinder valve.

2.Slowly loosen CO2 regulator assembly coupling nut allowing CO2 pressure to escape, then remove regula- tor assembly from empty CO2 cylinder.