‘‘SYRUP PRIME’’ Switches.

Side 1

Side 2

BLEND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON/OFF

SYRUP PRIME

ERROR

 

 

 

 

ON

RESET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTOR

 

 

 

 

 

 

 

ER

 

 

Display

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<(Backward)(Forward)>

Cancel Defrost

Manual Defrost

Menu/Select MS

FIGURE 2. CONTROL PANEL SWITCH IDENTIFICATION

‘‘SYRUP PRIME’’ Switches.

The ‘‘SYRUP PRIME’’ switches, located on the control panel, are touch-type switches and require only pressing to activate. The ‘‘SYRUP PRIME’’ switches are used only when filling the syrup systems sold-out floats during syrup replenishing, syrup flavor changeover, or sanitizing the syrup systems.

‘‘BLEND ON/OFF’’ Switches.

The ‘‘BLEND ON/OFF” switches, located on the control panel, are touch-type switches and require only press- ing to activate. These switches are used to fill the product blender tanks after the sold-out floats have been filled using the ‘‘SYRUP PRIME’’ switches. After the product blender tanks have been filled, the “BLEND ON/OFF” switches may be pressed again to prevent more product from entering the product blender tanks during BRIX test. The “ON” and “BLEND ON/OFF” switches must be pressed to operate the freeze cylinders beaters and refrigeration system during normal operation.

‘‘MOTOR’’ Switches.

The ‘‘MOTOR’’ switches, located on the control panel, are touch-type switches and require only pressing to acti- vate. These switches are used to operate the freeze cylinders beaters with no refrigeration during sanitizing.

’’ON’’ Switches.

The ‘‘ON’’ switches, located on the control panel, are touch-type switches and require only pressing to activate. These switches are used to operate the freeze cylinders beaters and refrigeration system after cylinders have been filled with product. The freeze cylinders beaters and refrigeration system may be stopped by pressing the ‘‘OFF’’ switches.

‘‘OFF’’ Switches.

The ‘‘OFF’’ switches, located on the control panel, are touch-type switches and require only pressing to activate. These switches are used to stop freeze cylinders beaters and refrigeration system.

‘‘ERROR RESET’’ Switch.

‘‘ERROR RESET’’ switch, located on the control panel, is a touch-type switch and requires only pressing to acti- vate. The ‘‘ERROR RESET’’ switch is used to restore normal operation after error within Unit (indicated by ‘‘ERROR 1’’ or ‘‘ERROR 2’’ on message display) has been corrected.