FlavorFusion®/FlavorOverload Training Manual

DIAGNOSTICS GUIDE FOR THE MAIN CONTROL BOARD (SEE FIGURE 22)

State

Observed State

Sensor Input

Control Response

Service Remedy

 

of Red LED

 

 

 

 

 

 

 

 

0

Flash rate 3

Both probes read “wet”

Standby mode.

No service required

 

seconds

 

Pump = OFF

 

 

 

 

 

 

1

Flash rate

Pump is OFF and HIGH

Waiting for level to

No service required

 

1/2 second

probe reads “dry” and LOW

drop below LOW

 

 

 

probe reads “wet”

probe. Pump = OFF

 

 

 

 

 

 

2

Flash rate

Both HIGH and LOW

Normal mode.

No service required

 

1/2 second

probes read “dry”

Pump = ON

 

 

 

 

 

 

3

Flash rate

Entered when HIGH probe

Normal mode.

No service required

 

1/2 second

does not detect liquid, and

Pump = ON

 

 

 

LOW probe does detect

 

 

 

 

liquid, and pump is ON

 

 

 

 

 

 

 

4

Flash rate 1

Entered when HIGH probe

THIS IS AN ERROR

- Check electrical

 

second

reads “wet” and LOW probe

CONDITION.

connections at the

 

 

reads “dry”

 

carbonator tank, and at

 

 

 

 

connector J4 on the main

 

 

 

 

control board

 

 

 

 

- Black wire should be

 

 

 

 

connected to the LOW

 

 

 

 

probe and also to Pin 4 of

 

 

 

 

Connector J4

 

 

 

 

- Reverse the connections

 

 

 

 

if incorrect

 

 

 

 

- Replace harness if

 

 

 

 

necessary

 

 

 

 

 

5

ON

Poor signal connection to

Able to continue to

Check the harness

 

continuously,

the carbonator tank. May

function but

connections of the red

 

but “flickers”

result in short cycling of the

carbonator pump

signal wire at both ends:

 

every 3

carbonator pump.

short-cycles. Pump

1) at the carbonator ring

 

seconds

 

will come on each

terminal and

 

 

 

time a drink is drawn.

2) at Pin 5 of the J4

 

 

 

THIS SITUATION

connector at the main

 

 

 

SHOULD BE

control board

 

 

 

CORRECTED.

 

 

 

 

 

 

6

ON

Entered when pump has

THIS IS AN ERROR

Unplug the unit and plug it

 

continuously

run continuously for 5

CONDITION.

back in. This will reset the

 

 

minutes

 

unit's main control board

 

 

 

 

and restart the carbonator

 

 

 

 

pump.

 

 

 

 

 

LED

FIGURE 22

© 2004-2007, IMI Cornelius Inc.

- 19 -

Publication Number: TP01070

Page 23
Image 23