FlavorFusion®/FlavorOverload Training Manual

VALVE SERVICE

NOTE: Before servicing the valve the BIB connector must be disconnected an the pressure must be relieved.

1.Remove the locking screw after removing the valve from its mounting block.

2.

Twist the solenoid 90o.

Spring Clip

Locking Screw

3.Pull the solenoid loose from the valve body.

4.To remove the tubing squeeze the spring clip together and pull off.

FIGURE 19

CARBONATOR TANK

Always disconnect water and CO2 and relieve the carbonator pressure before removing the car- bonator probe.

MOTOR REMOVAL

NOTE: Apply anti seizing lubricant to the threads of mounting bolts when service is required.

Grounding Connection/

Upper and Lower Level

CO2 Inlet

Control Probes

Relief

Valve

FIGURE 20

Heater, Agitation

Heater Spring

Motor, & Gear Box

Motor

Mounting

Screws

FIGURE 21

© 2004-2007, IMI Cornelius Inc.

- 9 -

Publication Number: TP01070

Page 13
Image 13
Cornelius TP01070 manual Valve Service, Carbonator Tank, Motor Removal