INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of door, at a minimum height of 5 feet (1.52 m) where small

children cannot reach, away from moving parts of door and door hardware.

1.Strip 1/4" (6 mm) of insulation from one end of bell wire and connect to the two terminal screws on

back of door control by color: white to 2 and white/red to 1.

2.Fasten the Door Control Button securely with 6ABx1-1/2" screws. If installing into drywall, drill 5/32" holes and use the anchors provided.

3.Run bell wire up walt and across ceiling to motor unit. Use insulated staples to secure wire in several places. Do not pierce wire with a staple, creating a short or open circuit.

4.Connect the bell wire to the terminal screws on the motor unit panel: white to 2; white/red to 1.

5.Position the antenna wire as shown.

6.Use tacks or staples to permanently attach entrapment warning label to wall near door control, and manual release/safety reverse test label in a prominent location on inside of garage door.

NOTE: DO NOT connect power and operate opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned.

2*Conductor Bell Wire

Bell

Screws

Tern_inatWire

To prevent possible SERIOUSINJURY or DEATHfrom electrocution:

Be sure power is not connected BEFOREinstalling door control.

Connect ONLYto 24 VOLTlow voltage wires.

To prevent possible SERIOUSINJURY or DEATHfrom a closing garagedoor:

Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet

(1.52 m), and away from all moving parts of door. NEVERpermit children to operate or play with door control push buttons or remote control transmitters.

Activate door ONLYwhen it can be seen clearly, is

properly adjusted, and there are no obstructions to door travel.

ALWAYSkeep garagedoor in sight until completely closed. NEVERpermit anyone to cross path of closing garagedoor.

Outside Keylock Accessory Connections

To lo.pener terminal screws: white to 2; white/red

HARDWARE SHOWN ACTUAL SIZE

'''''''''''n oated

Lighted Door Control Button

D_ywatl Anchors

Staples

Opener

Terminal Screws

(BACK VIEW)

DOOR CONTROL BUTTON